6-3-3 When the Indoor unit fan motor doesn't operate
1. Check if power(AC220V) is being supplied.
2. Check if the operating condenser(CR71, CR72) and connector(CN73, CN74) are properly assembled.
3. Put the fan in operation with the remote control and check if the fan is rotating after the auto grille is full open.
(If so, it is in norma operation)
4. If not, measure AC voltage of No. 5 and 3 of CN73, CN74.
• If the voltage value is 180~220V : Poor motor
• If not : Poor PCB
Troubleshooting
Samsung Electronics
22
MOTOR
MOTOR
Indoor Unit Fan Motor(L)
Indoor Unit Fan Motor(R)
CN73
Blue
MICOM
12V
SSR
+
IC07
CN74
White
Operating Condenser
CR71
1.2µF/450V
AC220V
60Hz
CR72
1.2µF/450V
#32
Red
!
#
%
!
#
%
Yellow
Green
Red
Yellow
Green
Operating Condenser
0V
12V