Samsung Electronics
6
2-3 Installation
2-3-1 Before Installation
Keep the air conditioner drain hose outlet and inlet free from its surroundings.
In case of breakdown, keep the symmetry and fix it to prevent vibration.
The pipe length shall meet the standard as far as possible.
2-3-2 Installation Procedure
■
Location
Install the product in an area to guarantee the best cooling effect, convenience of piping and electric work, and inexistence of
vibration or wind in the vicinity.
■
Wall Drilling
Drill the wall downward in a diameter of 60 to 65mm.
■
Fixing Indoor Unit & Outdoor Unit
Fix the air conditioner hard enough so that it can not fall to the ground. On the roadside, the outdoor unit shall be installed 2m
above ground and kept away from pedestrians to prevent direct exposure to hot wind.
■
Pipe Spooling & Connecting
You shall cut the pipe straightly with a pipe cutter and grind all the burrs of the cut surface.
Pipe expansion may continue until the pipe surface becomes uneven or torn apart.
Be sure to use a torque wrench to tighten pipes or flare nuts.
■
Leak Test
Put an inert gas like nitrogen in the outdoor unit pipe and put soap bubbles or other test liquids on the pipe surface for the leak test.
■
Drain Hose Connecting
Install the drain hose downward to drain water naturally. Be sure to pour water into the hose to check if it drains well.
■
Electric & Earth Work
Electric and earth work shall meet the "Electric Facility Technology Standard" and the "Internal Wire Regulation" of the Electric
Business Laws.
■
Inspection & Trial Run
Upon completion of the tests, you shall make a trial run while you explain the main functions of the air conditioner to finish the
installation.
Outer Diameter(D)
6.35mm(1/4")
12.70mm(1/2")
15.88mm(5/8")
Torque(kgf.cm)
140~170
380~420
440~480
Depth(A)
1.3mm
2.0mm
2.2mm
D
A
<Torque & Depth>
DB98-21337A(1) 05/1/4 2:19 AM Page 6