Flow Chart of Troubleshooting
9-8
9-5. Microphone Part
Check the connection
from MIC
Check the circuit
from UCP300 to MIC
Resolder MIC
Resolder the R600, R603, R604, R607
and TA600
END
No
Yes
Yes
Yes
OK
No
Check the MIC
No
Replace the MIC