SAMSUNG Proprietary-Contents may change without notice
3-1
This Document can not be used without Samsung's authorization
3. Chart of Troubleshooting
3-1. Baseband
3-1-1. Power ON
Check the Initial operation
'Power ON' Does not work
Check the current consumption
Current consumption
≥
100mA ?
Down load again
Voltage
≥
3.3V ?
R509
≥
2.4V ?
Check the Clock at
OSC500=32kHz
END
Charge the Battery
Check the PMIC related to
PS_HOLD
NO
NO
NO
YES
YES
YES
Resolder OSC 500
NO
YES
Check the PMIC(U500)
NO
Check U500
C511(MSMP_2.6V)=2.6V?
C513(MSMC_1.375)=1.375V?
C512(MSMA_2.6V)=2.6V?
C514(MSME_1.8V)=1.8V?
YES
Check the clock at
TCX800=19.2MHz
YES
check the clock generation
circuit(TCX800)
NO
YES