4.5.3 Detail Description (Engine Test Mode)
Function Name
Description
Display
01.Motor Test
The main motor starts when the execution key is pressed
Main Motor On/Off
and stops when the stop key is pressed.
02.Pick Up Test
Automatically stops, when the execution is chosen.
Tray 1,2 Solenoid On/Off
stops, when the execution is chosen.
03.Fan Test
The fan starts when the execution key is pressed and
Fan On/Off
stops when the stop key is pressed.
04.Manual Clutch Test
The tray2,3 clutch is on for 1sec and then it automatically
Tray 2,3 Clutch On/Off
stops, when the execution is chosen.On this function,
the main motor runs before 2sec from the point of the clutch
on in order to check the clutch state.
05.PTL Test
PTL(Pre-Transfer Lamp) is lights when the execution key
PTL On/Off
chosen and it stops when the stop key is chosen.
11.LSU Motor
The laser motor starts when the execution key is pressed
Laser Motor On/Off
and stops when the stop key is pressed.
12.LSU Hsync Test
The LSU motor starts and "Laser Ready" is displayed if
Laser Leady On/Off
the motor spins at the correct speed, otherwise "Laser Error"
is displayed.
13.LD Test
"Diode On" is displayed, when the laser diode is on.
Diode On/Off
Otherwise "Diode Off" is displayed.
21.Feed Sen Test
These functions allow the current state of the sensor to be
"Sensor Off" or “ Sensor On ”
22.Exit Sen Test
displayed.
23.Cover Sen Test
This function allows the current state of the Cover sensor
"Cover Open" or "Cover Close"
to be displayed. Touch the sensor and confirm that the
message changes: "Cover Open" to " Cover Close"
24.Empty Sen Test
These functions allow the current state of the sensor to be
"Sensor Off" or “ Sensor On ”
25.Manual Sen Test
displayed.
31.Them ADC 180
"Current value" is displayed on the upper line of the LCD,
Target temperature and
32.Them ADC 140
and "Target value" on the bottom line.
output temperature from
33.Them ADC 120
Target value is limited from "191°C" to "80°C"
thermistor and ADC.
34.Them ADC 100
41.MHV Test
These Functions are provided to check whether the
MHV On/Off
42.Dev Bias Test
control of the HVPS is functioning correctly.
Dev Bias On/Off
43.THV EN/NEG Test
THV EN/NEG On/Off
44.THV ON(1300V)
THV On/Off
45.THV ADC 1300V
ADC value displayed.
46.THV ADC 600V~3500
ADC value displayed.