Service Manual
Disassembly and Reassembly
5-8
Samsung Electronics
6. Remove the two screws securing the Scan Upper
Unit.
7. Release the seven hooks securing the Scan Upper
Unit to the Scan Lower Unit and remove it, as shown
below.
8. Using the right hand to push the Idle Pulley from right
to left, and the left hand to lift and remove the Belt.
9. When removing CIS FFC, note that the cable is taped
to the Scan Lower Unit. Then take the CIS(with
Carriage, Belt, CIS FFC) out of OPE Lower Unit.
10. To remove the CIS from the Carriage, first unplug
the CIS FFC from the CIS and remove two CIS
Slider from each end of the CIS. Then Release the
CIS in the direction of arrow, as shown below.
Belt
2
1
CIS FFC
CIS
Carriage
Belt
Scan Lower Unit
CIS Slider
CIS Slider
CIS
Carriage
CIS FFC
Scan Upper Unit
Scan Lower Unit