English
- 19
●
CONNECTION & INSTALLATION
Baud Rate Settings
Select the transfer speed of a selected communication protocol.
No
Baud Rate (BPS)
SW2-#5
SW2-#6
1
2,400
ON
ON
2
4,800
ON
OFF
3
9,600
OFF
OFF
4
19,200
OFF
ON
Communication Method Settings
Select a communication method for the camera.
Function
ON
OFF
SW2- #7
Transfer Mode Switch
RS-422 (4Wire)
RS-485 (2Wire)
Communication Response Settings
Select a communication response method for the camera and controller: Response or No Response.
Function
ON
OFF
SW2- #8
Response Mode Switch
Response
No Response
Termination Settings
To prevent the attenuation of communication signals between the camera and controller, the items at
the end of line must be set up with the termination settings.
Camera Input Position
SW2- #11
SW2- #12
Termination of Longest Path (RS-422)
ON
ON
Termination of Longest Path (RS-485)
ON
OFF
On the Path
OFF
OFF
Example of terminal setting
If using RS-422, SW2-#11: ON /SW2-#12: ON for camera 16
If using RS-485, SW2-#11: ON / SW2-#12: OFF for camera 16