| 4
RADVISION | RADVISION Port Security Reference Guide
SCOPIA Elite MCU
SCOPIA Elite MCU 5000 Series
Table 1-1
lists the ports supported by all the models in the SCOPIA Elite MCU 5000 Series, including
SCOPIA Elite 5100 Series MCU and SCOPIA Elite 5200 Series MCU.
Table 1-1
Ports Supported by SCOPIA Elite MCU 5000 Series
Port Range
Protocol
Functionality
Direction Result of Blocking Port
on Firewall
Description
21
FTP (TCP)
Audio stream recording In
Cannot record audio
streams
FTP Server
22
SSH (TCP)
MCU
In
Cannot view logs in real
time (logs are collected
on the compact flash
card)
SSH Client
80
(configurable)
HTTP (TCP)
MCU Administrator and
Conference Control
web user interfaces
In
Cannot administer MCU Web client
Used for software
upgrade
161
SNMP (UDP)
Configuration and
status
In
Cannot configure or
check the status of the
MCU via SNMP
iVIEW Network Manager,
iVIEW Management Suite
or any other SNMP
manager station
162
SNMP (UDP)
SNMP Trap events
Out
Cannot receive Traps
iVIEW Network Manager,
iVIEW Management Suite
or any other SNMP
manager station
443
HTTPS (TCP) Secure web interface
In
Cannot administer MCU
1024-1324
(configure
within this
range)
H.245 (TCP)
H.245 signaling
Both
Cannot connect H.323
calls
Any H.323 entity.
The SCOPIA Elite 5100
Series MCU uses 90 ports
for H.245, while the
SCOPIA Elite 5200 Series
MCU uses 180 ports.
To configure, use the
MCU Advanced
Commands section.
Enter the command
h245baseport to set the
lower port value, and
h245portrange to specify
the number of ports
above the base port to be
used.