BASIC TIMER and TIMER 0
S3C9454B/F9454B
10-8
TIMER 0 FUNCTION DESCRIPTION
Interval Timer Mode
In interval timer mode, a match signal is generated when the counter value is identical to the value written to the
Timer 0 reference data register, T0DATA. The match signal generates a Timer 0 match interrupt (T0INT, vector
00H) and then clears the counter. If, for example, you write the value "10H" to T0DATA, the counter will increment
until it reaches "10H". At this point, the Timer 0 interrupt request is generated, the counter value is reset and
counting resumes.
Comparator
CLK
Data Register (T0DATA)
Match
T0CON.3
Timer 0 counter clear
PND
IRQ0 (T0INT)
T0CON.1
Interrupt Enable/Disable
R (clear)
Counter (T0CNT)
NOTE:
T0CON.3 is not auto-cleared, you must pay attention when clear pending bit
(refer to P10-12)
Figure 10-5. Simplified Timer 0 Function Diagram (Interval Timer Mode)