S3C80A5B
CONTROL REGISTERS
4-25
SPL
— Stack Pointer (Low Byte)
D9H
Set 1
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
x
x
x
x
x
x
x
x
Read/Write
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Addressing Mode
Register addressing mode only
.7–.0
Stack Pointer Address (Low Byte)
The SP value is undefined following a reset.
STOPCON
— Stop Control Register
FBH
Set 1
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
0
0
0
0
0
0
0
0
Read/Write
W
W
W
W
W
W
W
W
Addressing Mode
Register addressing mode only
.7–.0
Stop Control Register enable bits
1
0
1
0
0
1
0
1
Enable STOPCON
NOTES
:
1. To get into STOP mode, stop control register must be enabled just before STOP instruction.
2. When STOP mode is released, stop control register (STOPCON) value is cleared automatically.
3. It is prohibited to write another value into STOPCON.