In Case of Tracking Failure
(1) Check the model number for Centralized controller and the
Transmitter.
(2) Check the communication status of Centralized controller and the
Transmitter.
• Main Address : When communication with outdoor unit is normal, main
address will be displayed.
• RMC Address : Below indication will be displayed. When communication
with outdoor unit become normal, Indoor unit address will
be displayed.
(3) Check the polarity between S-NET mini and the Centralized
controller.
•
If polarity of C1, C2 changes, communication will be suspended.
•
Make sure none of the cables are disconnected.
Type
Normal communication
Communication error
Centralized
controller
Pressing ON/OFF button enables
normal operation.
Power indicator and indoor unit indicators
will blink periodically.
Transmitter
displays right side of the 7-Segment.
No display.
displays on right side of the
7-Segment.
Transmitter 7-Segment display
Display
Message
Stand by position for communication with centralized controller.
Normal communication.
None
Communication is suspended with Centralized controller.
(Connection check required.)
Main Address
RMC Address
S-NET mini TRACKING
�������
• Display may vary depending on the Transmitter.
Contact service center for the detail.