TROUBLESHOOTING
4. TROUBLE-SHOOTING
4-2-8. When the Freezer Lamp does not light up
Note
1. When the Door is open, the Door S/W contact becomes open, and 5v applies to MICOM sensing
the Door Open. And, when 5v is sensed for more than 2 minutes, it sends out the Door Alarm at
intervals of 1 minute for 10 seconds. So, when there is defect in Door S/W, the Door Alarm can
occur at intervals of 1 minute (refer when repairing the unit).
2.The interior lamp operates based on the Door S/W operation.
DOOR Reed S/W
works normally?
Start
Replace DOOR S/W
NO
YES
When the Door is open,
voltage output between
CN76 #1 and #2 is over 10v?
Replace PCb
NO
YES
When the Door is open,
voltage output at LED Lamp
PCb terminals is over 10v?
Check Wire Cut,
Check if the output
is DC 12v
YES
Change PCb
Replace LED LAMP PCb
☞
Checking Wire Terminals
Measure voltage between PCb CN76 #1(Orange)- #2(brown)
☞
Checking Door Switch voltage
- PCb Sensor Check Point : v oltage between IC10 MICOM #57 or
CN30-"6"(Red) and Common PCb GND, v oltage between CN30-
"6"(Red) and PCb GND
Common PCb
Ground REG1 body
* Checking REED S/W
REED S/W operates by the magnetic power of
the magnets attached on Doors.
- Reed S/W magnetized
→
0 Ω (Door Closed)
- Reed S/W not magnetized
→
∞ Ω (Door Open)
When the power of the magnets are weak or the
Reed S/W location is shifted, it needs replacing.
NO
Door & MICOM State
Door
Door S/W
MICOM(#57)
Close
0v(Low)
Open
5v(high)
Note
* As the Door is open/close, the
Lamp Relay turns on and off the
Lamp.
Note
When the Door is open, the Door S/W contact becomes open, and 5v applies to MICOM sensing the Door Open.
At LED LAMP PCb
terminals inside the
freezer Room
TWIN 냉동고 SM.indd 53
2009.4.9 2:56:21 PM
Содержание RZ60EESW1
Страница 15: ...15 2 5 DIMENTION 2 Product Specifications TWIN 냉동고 SM indd 15 2009 4 9 2 55 41 PM ...
Страница 66: ...66 8 SCHEMATIC DIAGRAM 8 1 BLOCK DIAGRAM TWIN 냉동고 SM indd 66 2009 4 9 2 57 6 PM ...
Страница 67: ...67 8 SCHEMATIC DIAGRAM 8 2 CIRCUIT DIAGRAM TWIN 냉동고 SM indd 67 2009 4 9 2 57 53 PM ...