TROUBLESHOOTING
Self-Diagnosis Error Description
NO
LED
Blinking
Frequency
Item
Description
Trouble
Shooting
1
Twice
F-DEF
-SENSOR
Connector Slipped-Out or Open-
Contact, Wire Cut or Short-Circuited,
Abnormal Sensing Temp (higher than
+65℃ or lower than -50℃)
The voltage between MAIN PCB CN30-
"4(RED) ↔ 7(Gray)" should be within
4.5V~0.5V.
2
3 times
EXT-SENSOR
Connector Slipped-Out or Open-
Contact, Wire Cut or Short-Circuited,
Abnormal Sensing Temp (higher than
+65℃ or lower than -50℃)
The voltage between MAIN PCB CN31-
"1(WHT) ↔ 2(WHT)" should be within
4.5V~0.5V.
3
5 times
F-DEF-ERROR
[ Freezer Defrost Heater ]
Connector Slipped-Out or Open-
Contact, Wire Cut or Short-Circuited,
Defective Thermistor
Freezer Defrost When the defrosting
does not complete even after it does
defrosting for more than 120 minutes.
Remove the MAIN PCB CN70 and CN77
connectors from the MAIN PCB and
read the continuity between BROWN ↔
ORG wires. (It differs according to the
energy consumption.)
When it reads 0 Ohm, check the Heater
short and when it reads ∞ Ohm, check
if the Wire/Thermal Fuse or the Bimetal
is Open.
4
6 times
R-SENSOR
Connector Slipped-Out or Open-
Contact, Wire Cut or Short-Circuited,
Abnormal Sensing Temp (higher than
+65℃ or lower than -50℃)
The voltage between MAIN PCB CN30-
"5(ORG) ↔ 7(Gray)" should be within
4.5V~0.5V.
5
9 times
Rotary Error
PBA-Rotary Switch Slipped-Out or
Open-Contact, Wire Cut or Short-
Circuited,Switch Part Defect
The voltage between MAIN PCB CN30-
"3(BRN)↔ 7(Gray)" should be within
4.5V~0.5V.
6
10 times
Comp start
failure error
The error code is displayed when the
compressor has failed to start.
Check the soldering status of the
inverter PCB. (Check if any parts have
short-circuited). Check if the DC 16V
output is less than 13.5V. Check the
Comp and Cycle.
Compressor
IPM Fault Error
The error code is displayed when
the compressor IPM fault error has
occurred.
Comp location
detection error
The error code is displayed when the
compressor location detection failed.
Check the compressor wire connections.
Check the soldering status of the inverter
PCB. (Check if any parts have short-
circuite d). Check the Comp and Cycle.
Comp motor
constraint error
The error code is displayed when the
compressor motor is constrained.
Check if the compressor and the Cycle
is normal. Check the input voltage.
Check the soldering of the inverter PCB.
(Check if any parts have short-
circuited.)
Comp low
voltage error
The error code is displayed when the
AC Input Voltage is too low.
Check the input voltage. (This error
occurs when the input voltage is AC
106 V or lower.)
Check the input voltage. (This error