Confidential
Chapter 2 Installing System
RFV01U-D1A Installation Manual v2.0
44
Copyright © 2017, All Rights Reserved.
Table 16.
Parts and Tools for fixing RRH_1 Sector Wall Type (Standard & Side Installation)
Category
Description
Parts
M10 × 35L Hex. Bolt (washer assembly,
attached to the unit bracket)
1 EA
Recommended Torque Value
M10 Hex. Bolt
217 lbf
in (250 kgf·cm)
Working Tools
Torque Wrench (100~400 lbf·in), Torque Wrench Spanner head (apply Hex.
Head: 17 mm), Spanner (17 mm)
2
Hang the unit bracket hook of RRH side on the mounting bracket_front hook’s
groove and fix it using fasteners.
Figure 46.
Fixing RRH_1 Sector Wall Type (Standard Installation)
M10 Hex. Bolt
(washer assembly)
Unit Bracket Hook
Mounting Bracket_Front
Hook Groove