81
TROUBLESHOOTING
5) If Ambient Sensor has trouble
ERROR Code
Bad contact of connector/ insert correctly
Is
MAIN PCB Connector CN78 inserted
correctly?
Is
Ambient Sensor unit
normal?
Is the voltage between
MAIN PCB Connector CN78 ”8”(Sky-Blue)
and REG1-GND normal?
Is the
input voltage of IC01 MICOM #12
normal?
Start
NO
YES
YES
YES
YES
Replace the temperature sensor
NO
Recheck the wiring connection
NO(0.6V > Measurement < 4.6V)
Check the iced-solder, solder
bridging, disturbed solder
NO
No trouble with PCB and temperature sensor
Recheck the bad contact of the connection
** Measuring point of resistance value according to
Sensor **
Ambient : CN78-”8”
↔
“12” measuring resistance value
** Placed in the right top table of upper hinge.
** 0
Ω
: Short trouble /
Ω∞
: Open trouble
Sensor MICOM/Connector number
Voltage measured between 4.6V ~ 0.6V.
Measuring voltage of IC01 MICOM #12
CN78-"8"(Sky-Blue) and REG1-GND from
PCB typical Ground part are similar.
→
Check the measure on the voltage of Resistance,
R315 due to the SMD MICOM
☞
Checking method of Ambient Sensor resistance
CN78-”8”(Sky-Blue)
↔
"12"(Sky-Blue)
- Compare the temperature table after measurement.
DATA1.
Temperature table
Refer to circuit diagram in the manual
Ambient Connector CN78-"8"(Sky-Blue) to
REG1-GND PCB typical Ground
☞
Checking method of Ambient Sensor voltage
- Measure the voltage of Resistance R315(IC01 MICOM #12) on
PCB or CN78-"8"(Sky-Blue)
↔
REG1-GND
- Compare the temperature table after measurement.
Measuring voltage of CN78-"8"(Sky-Blue)
↔
REG1-GND are as
below
PCB Typical Ground
REG1-GND
Start
YES
YES
YES
Содержание RF23HT Series
Страница 21: ...21 Product Specifications 2 7 1 PRINCIPLE OF FREEZEER ...
Страница 24: ...24 Product Specifications 2 8 Cooling Air Circulation ...
Страница 112: ...112 6 Wiring Diagram 6 1 Model RF23HT This document can not be used without Samsung s authorization ...
Страница 114: ...114 Block Diagram 7 1 2 MODEL RF23HT ...