78
TROUBLESHOOTING
2) ICE Maker(FZ) Sensor has troubled
ERROR Code
Bad contact of connector/ insert correctly
Is MAIN PCB
Connector CN90 inserted
correctly?
Is ICE Maker(FZ)
sensor unit normal?
Is the voltage between
MAIN PCB Connector CN90-"9"(Red)
and REG1-GND normal?
Is input voltage of
IC01 MICOM #13 normal?
Start
NO
YES
YES
YES
YES
Replace the ICE Maker
NO
Check the contact of PCB &
Wire Terminal correctly.
NO(0.6V > Measurement < 4.6V)
Check the iced-solder, solder
bridging, disturbed solder.
Replace the PCB
-
This refrigerator has Dual Ice Maker,
so controlled two Ice Makers.
NO
No trouble with PCB and temperature sensor.
Recheck the bad contact of the connection.
** Measuring point of resistance value according to Sensor **
ICE MAKER(FZ) : CN90 9
↔
8 measuring
resistance value
** 0
Ω
: Short trouble /
Ω∞
: Open trouble
Sensor MICOM/Connector number
Voltage measured between 4.6V ~ 0.6V.
Measuring voltage of IC01 MICOM #13,
CN90-"9"(Red) and REG1-GND PCB typical Ground
part are similar.
→
Check the measure on the Resistance R904 due to the
SMD MICOM.
☞
Checking Method of ICE MAKER(R) Senser
resistance CN90 "9"(Red)
↔
8"(White)
- Compare the temperature table after the measure.
DATA1.
Temperature table
Refer to circuit diagram in the manual
ICE
Maker(F)
Connector CN90-"9"(Red) and REG1-GND
PCB common Ground
☞
Checking method of ICE Maker Seneor
- Measure the voltage of Resistance R904(IC01 MICOM #75) or
CN90-"9"(Red)
↔
REG1-GND.
- Compare the temperature table after the measure. Measuring
voltage of CN90-"9"(Red)
↔
REG1-GND.
typical PCB Ground
REG1-GND
Содержание RF23HT Series
Страница 21: ...21 Product Specifications 2 7 1 PRINCIPLE OF FREEZEER ...
Страница 24: ...24 Product Specifications 2 8 Cooling Air Circulation ...
Страница 112: ...112 6 Wiring Diagram 6 1 Model RF23HT This document can not be used without Samsung s authorization ...