TROUBLESHOOTING
6) If F DEF Sensor has trouble
Bad contact of connector/Insert correctly
Is Main PCB Connector
CN30 inserted correctly?
Is F DEF Sensor unit normal?
Is the voltage between
Main PCB Connector CN30-#6(Pink) and REG1,
Heat Sink normal?
Is the input voltage of IC10
MICOM #58 normal?
Start
NO
YES
YES
YES
YES
Replace temperature sensor
NO
Check the wiring connection.
NO (0.6V > Measurement < 4.6V)
Check Cold solder joint,
Short, Solder Touch
NO
No trouble with PCB and temperature sensor.
Recheck the bad contact of the connector.
** Measuring point of resistance value according
to Sensor **
F-DEF : CN30 #6
↔
#8 Measure the resistance value
**
∞Ω
: Short trouble /
∞Ω
: Open trouble
Sensor MICOM/Connector number
Voltage is measured between 4.6V ~ 0.6V
Voltage of IC10 MICOM #58 is same with the
measuring voltage of CN30-"6"(Pink) and REG1,
& Heat Sink from PCB common Ground part.
→
Check the measure on MICOM or, Sensor
Marking #4(R307).
DATA1.
Temperature table
ERROR Code
Refer to circuit diagram in the manual
F DEF Connector CN30-#6(Pink) and REG1
Start
YES
YES
YES
☞
Checking method of F DEF Sensor resistance
CN30-#6(Pink)
↔
#8(Gray)
-. Compare with the temperature table after
measuring.
☞
Checking method of F DEF Sensor voltage
-. Measure the voltage of Sensor Check Point #4(IC10 MICOM
#58) on PCB or CN30-"6"(Pink)
↔
REG1, Heat Sink.
-. Compare with the temperature table after measuring.
Below is the measuring voltage of CN30-"6"(Pink)
↔
REG1, Heat Sink
Common PCB
Ground of REG1 Heater Sink
Содержание RF18 Series
Страница 16: ... AXIAL FLOW FAN AXIAL FLOW FAN 16 PRODUCT SPECIFICATIONS 2 8 Cooling Air Circulation ...
Страница 61: ...87 6 2 Connector Layout with part position Main Board PCB DIAGRAM ...
Страница 62: ...87 6 2 Connector Layout with part position Main Board RF18 RF20 PCB DIAGRAM 14 12V ...
Страница 63: ...88 7 Wiring Diagram RF18 RF20 RF195 RF197 RF215 RF217 ...
Страница 64: ...89 8 1 Refrigerator Block Diagram 8 Schematic Diagram ...
Страница 65: ...90 SchematicDiagram 8 2 Main ...