Field settings to set, see user manual for a full list
•
2011 -2
low ambient setting for optimisation set to -5 in Scotland
•
2012 +15
high ambient temp for optimisation
•
2021 45-50
Flow temperature in cold weather 50C for rads 45C for ufloor
•
2022 37C
Flow temperature in mild weather 37 for rads 37C for ufloor
•
2091 1 tells unit to look for a run signal on terminal B22
•
4021
1
tells unit a backup heat pump is present
•
4024
+10
tells unit not to use the backup heater if ambient is above +10C
# it is possible to scroll through the days & select every day, then legionella can be run daily
rather than weekly.
Electrically testing the unit:
It is possible to test each component one after another using a service function. You can use
this to make sure you have wired everything correctly.
To access service mode press
blue
set
button
and
test
button together for 6 seconds.
The controller will display TEST.
Press the
top left
button the unit will run the pump.
To test the external run signal or stat is connected adjust
temperature on stat up.
Heat1 will replace test on screen.
To exit service mode press and hold
cancel delete
for 6
seconds
Test 1
Firstly in test mode run the pump, press
blue
set
button
and
test
button together for 6
seconds. The controller will display TEST. Immediately press the top left button to turn the
pump on and leave it running while in test mode. When the pump is running a little house with
a circle around it in the status window of the controller.
The unit wants to see at least 17 l / min flow to activate
the flow switch, if there is not enough flow the unit will
never operate. You should have a flow meter installed,
if you haven’t now is the time to buy one.
If you look into the flow meter you can see the flow in
litres per minute. In this picture you can see a flow rate
indicated, this shows 25l/min NOT 35l/min
If the flow rate is too low you need to fix this before moving on.
Содержание RC160MHXEA
Страница 1: ...www samsungehs co uk G Hendra January 2015 1 Installer Please Read Instructions Inside ...
Страница 2: ...www samsungehs co uk G Hendra January 2015 2 ...
Страница 7: ...www samsungehs co uk G Hendra January 2015 7 Wiring diagram for heating and HW heat pump ...
Страница 8: ...www samsungehs co uk G Hendra January 2015 8 ...
Страница 9: ...www samsungehs co uk G Hendra January 2015 9 ...