Designing a 1 x N single-side enclosure
• When installing the display along with an enclosure, ensure adequate clearance (
A
) between the back of the
enclosure and surrounding objects for proper flow of air.
–
Example 1) Exposure to direct sunlight:
100 mm or more
–
Example 2) Atmospheric temperatures under
35
℃ without direct sunlight:
50 mm or more
• To install multiple displays side by side in landscape orientation, make sure you install separate fans, as shown
below, to maintain a flow rate of at least 150 CFM so as to prevent the displays from being affected by one another
due to the intake/exhaust air. The external air temperature should be maintained below
30
°C, as shown below
(measured position:
B
).
–
If the unit is subjected to excess heat due to an insufficient gap, this may cause a malfunction, which will not be
covered by the warranty.
A
B
Side
Wall
Lower inlet
Exhaust fan (total flow rate > 150
CFM)
Back
English - 11