3.5 RINGS AND TONES
3.5.1 RING CYCLES
The OfficeServ 7200-S provides the trunk line rings, station rings, door rings, and alarm rings. The ON/OFF cycle of
each ring is shown in the table below (it is different according to the country, and can be modified by MMC pro-
gramming).
Note: The ON/OFF cycle can be adjusted by changing the values of the system database.
3.5.2 RING
The output voltage and frequency of the ring signals in the OfficeServ 7200-S are as follows:
•
Output voltage: 75 Vrms Square Wave (Built in SLI)
•
Frequency: 20 or 25 Hz
The OfficeServ 7200-S provides the users with various tones to notify the users of the status of functional opera-
tions. The ON/OFF cycles of currently specified tones are shown in the table on the next page.
Note: The ON/OFF cycle can be adjusted by changing the values of the system database.
3.3
3.5.1a SYSTEM RING CYCLES
RING
ON/OFF CYCLE
TRUNK LINE RING
1000/2000 ms
STATION RING
400/200/400/3000 ms
DOOR RING
400/200/400/200/400/2000 ms
ALARM RING
400/200/400/200/400/200/400/1000 ms
3.5.3 SYSTEM TONES
TONE
ON/OFF CYCLE
DIAL TONE
1000/250 ms
BUSY TONE
500/500 ms
DO NOT DISTURB TONE
250/250 ms
RING BACK TONE
1000/2000 ms
CALL PARK TONE
CONTINUOUS
CONFIRMATION/CAUTION/BARGE-IN TONE
50/50 ms
CALL BACK/HOLD TONE
500/3500 ms
RING BACK TONE
1000/2000 ms
ERROR/NUMBER UNOBTAINABLE TONE
250/250 ms
MESSAGE CAMP ON TONE
CONTINUOUS