3. Disassembly and Reassembly
3-30 Replacing the Assy Safety Valve
Parts
Explanation Photo
Explanation
Cover Motor
Gas Line (2)
5
.
Using a tubing wrench and a channel-lock
wrench, disconnect the 2 gas lines from the
ASSY VALVE SAFETY . Do not bend or crimp gas
lines during removal .
6
.
Remove
gas fittings from the ASSY VALVE
SAFETY .
7
.
Remove 7 screws and the ASSY VALVE SAFETY,
Tube Bake and Holder Bake Nozzle from the
back wall of the storage drawer opening .
8
.
Install the new ASSY VALVE SAFETY, and Holder
Nozzle Bake on the back wall of the storage
drawer with 7 screws .
9
.
Reconnect wire connectors in their original
positions .
NOTE
Check
all gas lines and fittings for leaks before
operation .
WARNING
Cross-wiring the wires to the gas control valve
creates an explosion hazard that can result
in death, personal injury, and/or property and
product damage .
10
.
Reconnect All gas lines to the ASSY VALVE
SAFETY, Tube Bake and Holder Nozzle Bake .
11
.