Installation requirements
Special gas requirements (gas models sold in massachusetts)
COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS:
WARNING
Gas leaks may occur in your system, creating a dangerous situation.
– Gas leaks may not be detected by smell alone.
– Gas suppliers recommend you purchase and install a UL-approved gas detector.
Gas detector should be installed in accordance with the manufacturers
instructions.
•
Range must be installed by a qualified plumber or gas fitter by the State of
Massachusetts.
•
A T-handle manual gas valve MUST be installed in the gas supply line to your
range.
•
If a flexible gas connector is used to install your range, multiple flexible gas lines
must not be connected in series.
Electrical requirements
WARNING
To reduce the risk of fire, electric shock, or personal injury:
All ranges
•
Do not use an extension cord or adapter plug with this range.
•
This range must be properly grounded.
•
Check with a qualified electrician if you are in doubt as to whether your range is
properly grounded.
•
Do not modify the plug provided with your range—if it doesn’t fit the outlet, have
a proper outlet installed by a qualified electrician.
•
All wiring and grounding must be done in accordance with local codes or, in the
absence of local codes, with the National Electrical Code, ANSI/NFPA No. 70 –
Latest Revision (for the U.S.) or the Canadian Electrical Code CSA C22.1 – Latest
Revisions and local codes and ordinances.
•
Wiring diagram is located on the back of the range. (Inside of the cover back wire)
•
This range is equipped with an electronic ignition system that will not operate if
plugged into an outlet that is not properly polarized.
Gas models
•
All gas models are equipped with a power cord with an equipment-grounding
conductor and a grounding plug.
•
A 120-Volt, 60-Hz, AC, approved electrical service with 20-amp circuit breaker or
time-delay fuse is required for all U.S. and Canadian models.
•
Check for ¾-in (1.9-cm) UL-listed strain relief where the power cord comes out of
the range cabinet.
•
Do not reuse a gas supply flexible connector from an old range or other
appliance.
•
The power cord electric supply wiring must be retained at the range cabinet with
a suitable UL-listed strain relief.
•
A time-delay fuse or circuit breaker is also recommended.