installation_
5
installation
Safety instructions for the installation
This oven may be installed only by an approved electrician. The installer is responsible for
connecting the appliance to the mains and in so doing for observing the relevant safety regulations.
•
Ensure protection from live parts when installing the oven.
•
The kitchen cabinet in which the oven is built in must satisfy stability requirements as specified in
DIN 68930.
Technical specifications
Input voltage/Frequency
Volume (usable capacity)
Output rating
Net weight
Weight with packaging
Housing (W x H x D)
Oven interior (W x H x D)
230 V ~ 50 Hz
66 ℓ
max. 3400 W
approx. 29 kg
approx. 34 kg
595 x 595 x 566 mm
440 x 365 x 405 mm
Power connection
If the appliance is not connected to the mains with a plug, a
multi-pole isolator switch (with at least 3 mm contact spacing)
must be provided in order to satisfy safety regulations. The
power cable (H05 RR-F or H05 VV-F, min. 1.5 m, 1.5 ~ 2.5
mm²) must be of sufficient length to be connected to the oven,
even if the oven stands on the floor in front of its built-in cabinet.
Open the rear connection cover of the oven with a screwdriver
and loosen the screws of the cable clamp before you connect
the power lines to the relevant connection terminals. The oven
is earthed via the ( )-terminal. If the oven is connected to the mains with a plug, this plug must
remain accessible after the oven is installed. Samsung will take no responsibility for accidents that
originate from a missing or faulty earth connection.
Installation in the cabinet
This is a built-in oven, which needs to be installed into an upper or
lower cabinet.
•
Observe minimum distances.
•
Fix oven on both sides using screws
After installation, remove the vinyl protective film from the door to
the appliance and the protective film from the interior surfaces of the
oven.
INS
TALLA
TION
566
595
572
560
595
21
min. 550
min.550
min.600
Lower cabinet
min. 560
min. 50
min. 600
min. 50
min.560
Air flow
Upper Cabinet
min. 560
min. 50
min. 590
max. 600
Upper cabinet
min. 550
NV6312DGSSR_EE_DG68-00447T_EN.indd 5
2012-07-24 �� 1:52:36