50
4. Troubleshooting
This document can not be used without Samsung’s authorization.
4-2 Electrical Malfunction
Component testing procedures
WARNING
ELECTRICAL SHOCK HAZARD
Disconnect power before servicing the range
.
Replace all panels before operating range
.
Failure to do so can result in death or electrical shock
.
FIGURE
TESTS MEASURE
RESULTS
Broil Heater
*
Measure resistance value of the
heater terminals after removing
connectors from the heater
.
*
Measure voltage of heater terminals
after selecting broil
.
*
Approx : 11~15Ω
(at the room temperature)
*
Terminal voltage of Broil heater :
AC 240V
*
Replace or repair harness
*
Replace or repair main PCB of
each oven
.
(Upper oven : Wall main PCB,
Lower oven : New FM PCB
.
)
Bake Heater
*
Measure resistance value of the
heater terminals after removing
connectors from the heater
.
*
Measure voltage of heater terminals
after selecting bake
.
(Make sure that
voltage is measured for more than 1
minute because heater element will
cycle On and Off
.
)
*
Approx : 18~21Ω
(at the room temperature)
*
Terminal voltage of bake heater :
AC 240V
*
Replace or repair harness
*
Replace or repair main PCB of
each oven
.
(Upper oven : Wall main PCB,
Lower oven : New FM PCB
.
)
Convenction Heater
* Measure resistance value of the
heater terminals after removing
connectors from the heater
.
* Measure voltage of heater terminals
after selecting convection bake
.
(Make sure that voltage is measured
for more than 1 minute because
heater element will cycle On and Off
.
*
Approx : 40~46Ω(at the room
temperature)
*
Terminal voltage of convection
heater : AC 240V
*
Replace or repair harness
*
Replace or repair main PCB of
each oven
.
(Upper oven : Wall main PCB,
Lower oven : New FM PCB
.
)
Steam Heater
*
Measure resistance value of the
heater terminals after removing
connectors from the heater
.
*
Measure voltage of heater terminals
after selecting steam bake
.
(Make
sure that voltage is measured for
more than 1 minute because heater
element will cycle On and Off
.
*
Approx :
26~30Ω
(at the room temperature)
*
Terminal voltage of Drawer
heater : AC 120V
*
Replace or repaire harness
*
Replace or repaire Wall Main
PCB