English 11
Ins
tallation ins
truc
tions
Electrical Connection Options Chart
If your home has:
Go to section:
4-wire
(1.3 cm)
½”
4-Wire Cable from Home Power Supply
3-wire
(1.3 cm)
½”
3-Wire Cable from Home Power Supply
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge solid copper wire.
Electrically ground oven.
Failure to follow these instructions can result in death, fire, or electrical shock.
4-Wire Cable from Home Power Supply
IMPORTANT:
Use the 4-wire cable from home power supply in the U.S. where local
codes do not allow grounding through neutral, New Branch circuit installations
(1996 NEC), mobile homes and recreational vehicles, new construction and in
Canada.
A
E
B
G
H
I
C
D
F
A.
Cable from home power
supply
B.
Black wires (normally L1)
C.
Red wires (normally L2)
D.
4-wire flexible conduit from
oven
E.
Junction box
F.
White wires (normally
N-neutral)
G.
UL listed wire connectors
H.
green wires (normally
G-ground)
I.
UL listed or CSA approved
conduit connector
1.
Connect the 2 black wires (B) together
using a UL listed wire connector.
2.
Connect the 2 red wires (C) together
using a UL listed wire connector.
3.
Connect the 2 white wires (F) together
using a UL listed wire connector.
4.
Connect the green (or bare) ground
wire (H) from the oven cable to the
green (or bare) ground wire (in the
junction box) using a UL listed wire
connector.
5.
Install junction box cover.
Install_NQ5300R_NQ70R5511DG_AA_DG68-01149A-02_EN.indd 11
2019-05-09 12:05:55