Prepare the location

Wood filler strips

(recessed cabinet

bottoms only)

Wall

Cabinet

bottom

A

A

1. 

If cabinet has recessed bottom, add wood filler strips on each side. 

Install 4 flat head wood screws with washers and nuts to attach filler 

strips in locations shown.

NOTE

For installations to a surface other than drywall, it is recommended that a 

qualified contractor determine the anchoring method.

NOTE

Consider use the A measure for 7”(17.8 cm) round transition and B 

measure for recirculating system.

A

B

A. 14½” (36.7 cm)
B. 12 1/4” (31.1 cm)

2. 

Remove the grease filter by pulling the filter latch toward the back of 

the range hood and using a Torx T10 adapter, remove the screw from 

the filter retainer.

3. 

Remove the lateral panels by pulling them horizontally to the back of the 

hood and then release the brackets on the front.

4. 

Using 2 or more people, lift the range hood up under cabinet and 

determine final location by centering beneath cabinet. Mark on the 

underside of cabinet the location of the 4 keyhole mounting slots on 

the range hood (A) 

NOTE

Mark the thin area of the slot. On the back wall mark the holes for the 

security screws (B). Set range hood aside on a covered surface.

A

A. Keyhole slot

5. 

Use 

1

8

” (3 mm) drill bit and drill 4 pilot holes. 

NOTE

Make the drill holes on the thin area of the slot.

A

A. Drill pilot hole

Install the 4 - .45 cm x 1.3 cm mounting screws in pilot holes. Leave 

about ¼” (6.4 mm) space between screw heads and cabinet to slide 

range hood into place

1⁄4"

 

(6.4 mm)

6. 

Use 

8

25

" (8mm) drill bit and drill 2 pilot holes in the marks for the 

security screws, then place the drywall anchors.

B

Prepare Range Hood

1. 

Set the range hood on its back on a covered surface.

2. 

Unscrew and remove junction box cover

Installation Instructions

Installation Instructions

Содержание NK30B3500US

Страница 1: ...Range Hood Hotte de la cuisine Campana de cocina LIB0175247 ...

Страница 2: ...Venting Methods 7 Installation Instructions 7 Prepare the location 8 Prepare Range Hood 8 Mark Hole Locations 9 Mark and Cut Vent Opening 9 Drill Electrical Opening 10 Prepare Range Hood Vents 10 Attach Vent Damper or Transition 10 Mounting the Hood 11 Connect Vent System 11 Electrical Connection 11 Completing the installation 11 Range Hood Use and Care 12 Range Hood Description 12 Range Hood Cont...

Страница 3: ...rence in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception...

Страница 4: ...FIRE Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings Always turn the hood ON when cooking at high heat or when flambeing food i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flambé Clean ventilating fans frequently Grease should not be allowed to accumulate on the fan or filter Use pr...

Страница 5: ... clamps to seal all joints in the vent system The vent system must have a damper If the roof or wall cap has a damper do not use the damper supplied with the range hood Use caulking to seal the exterior wall or roof opening around the cap The size of the vent should be uniform Venting Methods To use the hood s top outlet to vent your hood a 3 x 10 8 3 x 25 4 cm rectangular with a maximum vent leng...

Страница 6: ... utility knife Tape measure or ruler Pliers Caulking gun and weatherproof caulking compound Saber or keyhole saw Metal snips Screwdrivers 2 Phillips Flat blade Parts needed Home power supply cable 12 7 mm UL listed or CSA approved strain relief 3 UL listed wire connectors For 7 17 8 cm round vented installations 7 17 8 cm round mental vent system with wall or roof cap Vent clamps For 3 x 10 8 3 x ...

Страница 7: ...e 31 4 x 10 8 3 x 25 4 cm rectangular with a maximum vent length of 35 ft 10 7 m or 7 17 8 cm or larger round vent with a maximum length of 50 ft 15 2 m for vent system Use the diagram or the hood as a template and mark the locations for the ductwork electrical wiring and keyhole screw slots D C CL E FRONT OF THE HOOD WALL B A 3 95 cm 11 2 7 17 8 cm 8 3 cm 10 25 4 cm 31 4 A 30 76 cm B 187 8 48 cm ...

Страница 8: ...nd then release the brackets on the front 4 Using 2 or more people lift the range hood up under cabinet and determine final location by centering beneath cabinet Mark on the underside of cabinet the location of the 4 keyhole mounting slots on the range hood A NOTE Mark the thin area of the slot On the back wall mark the holes for the security screws B Set range hood aside on a covered surface A A K...

Страница 9: ...erside of the cabinet Drill a 7 8 2 2 cm diameter hole B through the rear wall at this point B A 7 8 2 2 cm A 8 2 5 21 3cm Mark and Cut Vent Opening For a non vented recirculating installation skip Mark and Cut Vent Opening step For 3 x 10 8 3 x 25 4 cm Rectangular Vent System Roof Venting To make a 4 x 10 10 16 cm x 26 7 cm rectangular cutout on the underside of cabinet top and bottom 1 Mark line...

Страница 10: ...trical Opening 1 Using a 1 3 cm drill bit drill the hole in the dot marked previously at the electrical strain relief Prepare Range Hood Vents A B C D E Install Strain Relief 1 Install a UL listed CSA approved 13 mm strain relief A For non vented Recirculating Installations Remove the 2 T10 Torx screws and remove the top front rectangular vent cover E Go to Electrical Connection step When used in ...

Страница 11: ...System 1 Connect the vent work to the range hood 2 Seal joints with vent clamps or duct tape to make secure and airtight 3 Check that the backdraft dampers work properly Electrical Connection WARNING ELECTRICAL SHOCK HAZARD DISCONNECT POWER BEFORE SERVICING REPLACE ALL PARTS AND PANELS BEFORE OPERATING FAILURE TO DO SO CAN RESULT IN DEATH OR ELECTRICAL SHOCK A B C D E F G A White wires B Black wir...

Страница 12: ...ded replace the metal grease filter When washed in a dishwasher the grease filter may discolor slightly but this does not affect its filtering capacity To replace metal grease filter 1 Remove the filter by pulling the latch toward the back of the range hood and using a Torx T10 adapter remove the screw from the filter retainer replace the filter and place the screw back Metal grease filter is not ...

Страница 13: ...fore wiring 1 MOUNT THE SWITCH BOX Install a 3 deepsingle gang switch box 2 ATTACH THE POWER CABLE Clamp wiring to the switch box and unit using an appropriate clamp Provide 6 leads inside the box and fan for easier wiring 3 CONNECT THE WIRING General instructions Make sure both the switch box and the appliance are properly grounded Make sure the ground wire is securely fastened to the control s g...

Страница 14: ...ystems utilities services parts supplies accessories applications installations repairs external wiring or connectors not supplied or authorized by SAMSUNG which damage this product or result in service problems incorrect electrical line voltage fluctuations and surges customer adjustments and failure to follow operating instructions cleaning maintenance and environmental instructions that are cov...

Страница 15: ...llations repairs external wiring or connectors not supplied or authorized by SAMSUNG which damage this product or result in service problems incorrect electrical line voltage fluctuations and surges customer adjustments and failure to follow operating instructions cleaning maintenance and environmental instructions that are covered and prescribed in the instruction book problems caused by pest inf...

Отзывы: