![Samsung NE59J7630SS Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/samsung/ne59j7630ss/ne59j7630ss_service-manual_4148704049.webp)
49
4. Troubleshooting
4-2 Electrical Malfunction
RC radiant element
(No heating or
Abnormal working)
*Check element of RC radiant.
*Check whether harness connected
wire and the state of element of RC
radiant are in normal.
No
Fig.15 The drawer of connected wire of harness
Ok
Ok
Ok
Ok
*Check whether harness in
terminal of radiant has been
loosen or disconnected.
*Weld with terminal not to be misconnected
if harness is disconnected from terminal
on switch.
It is very dangerous when radiant heater is
working in case that harness has misconnected.
*Tighten terminal of harness by
compressing not to be loosen.
(Continued)
Ok
Ok
*Check whether harness is connected with
warming zone relay on Main PCB has been
damaged or disconnected.
Fig.14 RC radiant element
Position ohms
"A"-"B"
"C"-"D"
a
WARNING
(at the room temperature)
END
END
END
RC radiant element
Assembly RC cooktop
“D”
“D”
“C”
“C”
“A”
“A”
“B”
“B”
Position
Color
“
A
”
violet (red)
“
B
”
red (violet)
“C”
yellow
“D”
yellow