45
4. Troubleshooting
4-2 Electrical Malfunction
LR radiant element
(No heating or
Abnormal working)
* Check the element of LR Radiant
*Check whether harness connected
wire and the state of element of LR
radiant are in normal.
No
Fig4. The drawer of connected wire of Harness
Ok
Ok
Ok
Ok
*Check whether harness in
terminal of radiant has been
loosen or disconnected.
*Weld with terminal not to be
misconnected if harness is disconnected
from terminal on radiant.
It is very dangerous when radiant heater is
working in case that harness has misconnected
*Tighted terminal of harness by
compressing not to be loosen.
(Continued)
Ok
*Check whether harness is connected with
LR infinite switch has been damaged or
disconnected.
Position color
remark
“A”
2a
1b
2b
yellow
yellow
black+brown
red
240V,1200W
165N8-L6871R
single element
Ceramaspeed Co.
Fig3. LR radiant element
Position ohms
1b-2b
2a-"A"
45~50
WARNING
END
END
END
Assembly LR Cooktop
Assembly LR Cooktop
LR radiant element
LR radiant element
“A”
“A”
1b
1b
2b
2b
2a
2a