11
3. Disassembly and Reassembly
3-1
5HPRYLQJ&RYHU%DFN0DLQ:LUH&RYHU%DFN*XDUG:LUHDQG3&%0DLQ
WARNING
ELECTRICAL SHOCK HAZARD
Disconnect power before servicing the range. Replace all panels before operating range. Failure to do so
can result in death or electrical shock.
PRECAUTION
When you work on the electric range, be careful when handling the sheet metal parts. Sharp
edges may be present, and you can cut yourself if you are not careful.
Parts
Explanation Photo
Explanation
Cover-Back Main
Wire, Cover-
Back Guard Wire
and PCB-Main
Cover-Back
Guard Wire
Cover-Back
Main Wire
1.
Turn off the electrical supply
going to the range.
2.
Pull the range away from the
wall so that you can access the
rear panel.
3.
Remove the 8 screws from the
Cover-Back Main Wire and
remove the panel.
4.
Remove 3 screws from the
Cover-Back Guard Wire and
remove the cover.
5.
Remove 2 screws of PCB-Main
and separate PCB-Main.
* Reassembly of All part is the reverse order of disassembly.
Screw
- Terminal Block Screw : M4 X 18.
- The others : M4 X 12.
PCB Main
1(5$%65B$$LQGE