Setting an indoor unit address and installation option

You can change each digit of set option.

Changing a particular option 

Option 

SEG1

SEG2

SEG3

SEG4

SEG5

SEG6

Explanation

PAGE

MODE

The option mode 

you want to 

change

The tens’ digit of an 

option SEG you will 

change

The unit digit of 

an option SEG you 

will change

The changed value

Remote 

Controller 

Display

Indication 

and 

Details

Indication Details Indication Details Indication Details Indication Details Indication Details Indication Details

0

D

Option 

mode

0~F

Tens’ digit 

of SEG

0~9

Unit digit 

of SEG

0~9

The 

changed 

value

0~F

•    When changing a digit of an indoor unit address setting option, set the SEG3 as ‘A’.
•    When changing a digit of indoor unit installation option, set the SEG3 as ‘2’.

Ex) When setting the 'buzzer control' into disuse status. 

Option 

SEG1

SEG2

SEG3

SEG4

SEG5

SEG6

Explanation

PAGE

MODE

The option 

mode you want 

to change

The tens’ digit of 

an option SEG 

you will change

The unit digit of 

an option SEG 

you will change

The changed 

value

Indication 

0

D

2

1

7

1

ND***4HXEA_IM_E_33497A(1).indd   24

2011-03-08   오후 2:00:33

Содержание ND 4HXEA Series

Страница 1: ...nstallation manual imagine the possibilities Thank you for purchasing this Samsung product To receive more complete service please register your product at www samsung com register E DB98 33497A 1 ND 4HXEA_IM_E_33497A 1 indd 27 2011 03 08 오후 2 00 34 ...

Страница 2: ...nty Theairconditionershouldbeusedonlyfortheapplicationsforwhichithasbeendesigned theindoorunitisnotsuitabletobe installedinareasusedforlaundry Donotusetheunitsifdamaged Ifproblemsoccur switchtheunitoffanddisconnectitfromthepowersupply Inordertopreventelectricshocks firesorinjuries alwaysstoptheunit disabletheprotectionswitchandcontactSAMSUNG s technicalsupportiftheunitproducessmoke ifthepowercable...

Страница 3: ...nit in such conditions first consult your dealer Avoid installing the air conditioner In areas where it is exposed to direct sunlight Close to heat sources In damp areas or locations where it could come into contact with water for example rooms used for laundry In areas where curtains and furniture could affect the supply and discharge of air Without leaving the required minimum space around the u...

Страница 4: ...Maintain sufficient clearance around the indoor unit Make sure that the water dripping from the drain hose runs away correctly and safely The indoor unit must be installed in this way that they are out of public access Not touchable by the users Insulation cover band Insulation pipe Cable tie Drain hose Installation manual Clamp If you install the cassette type indoor unit on the ceiling with humi...

Страница 5: ...eople or things Do not hold the discharge while carrying the indoor unit to avoid the possibility of breakage You must hold the hanger plate on the corner and carry the indoor unit MODEL ND0454HX ND0564HX ND0714HX ND0904HX ND1124HX ND1284HX ND1404HX C mm 251 293 335 Net dimension mm 840 204 840 840 246 840 840 288 840 Required space for an indoor unit installation Obstruction 20mm 17mm 1500mm or m...

Страница 6: ...8 840 840 288 840 Net weight kg 15 5 15 5 17 5 19 5 Liquid pipe connection 1 4 3 8 Gas pipe connection 1 2 5 8 Drain Hose connection mm OD Ф32 0 ID Ф26 5 Drawing of the indoor unit 890 910 Celling opening 950 735 Suspension position 890 910 Celling opening 735 Suspension position Sub duct connection 55 840 370 346 185 96 950 120 45 86 164 216 55 55 840 330 240 270 300 ND 4HXEA_IM_E_33497A 1 indd 6...

Страница 7: ...he indoor unit 2 Adjust a space between the ceiling and the indoor unit by using the gauge of dimensions 3 Fix the indoor unit securely after adjusting level of the unit by using a leveler 4 Remove the pattern sheet connect the other cables and install the front panel Since the diagram is made of paper it may shrink or stretch slightly due to temperature or humidity For this reason before drilling...

Страница 8: ...n gas insert gas Therefore all insert gas must be purged before connecting the assembly piping Unscrew the pinch pipe at the end of each refrigerant pipe RESULT All inert gas escapes from the indoor unit To prevent dirt or foreign objects from getting into the pipes during installation do NOT remove the pinch pipe completely until you are ready to connect the piping If the pipes must be shortened ...

Страница 9: ...anually and then with a torque wrench applying the following torque Cutting flaring the pipes In case of needing brazing you must work with Nitrogen gas blowing Uneven Thickness Cracked Damaged Surface Inclined Correct Oblique Rough Burr Flaring tool Clutch type Wing nut type A Die Copper pipe York Die Copper pipe Flare nut Outer diameter mm A mm Flare tool for R410A clutch type Conventional flare...

Страница 10: ...d to the wall with suitable ducts If the pipes require brazing ensure that OFN Oxygen Free Nitrogen is flowing through the system Leak test Insulation No gap NBR T13 0 or thicker Insulation cover pipe Indoor unit Be sure to overlap the insulation Insulation pipe Must fit tightly against body without any gap Always make the seam of pipes face upwards All refrigerant connection must be accessible in...

Страница 11: ...tionpartofittopreventmoisture fromentering Windtherefrigerantpipewithinsulationtapeifitisexposedtooutsidesunlight Installtherefrigerantpiperespectingthattheinsulationdoesnotgetthinneronthebentpartorhangerofpipe Addtheadditionalinsulationiftheinsulationplategetsthinner Additional insulation Hanger Refrigerant pipe insulation a 3 a Pipe Pipesize InsulationType Heating Cooling Remarks Standard 30 C 8...

Страница 12: ... and upward gradient after the connection port This will cause water to flow backwards when the unit is stopped resulting in water leaks Air ventilation Ceiling Install air ventilation to drain condensate water smoothly Do not apply force to the piping on the unit side when connecting the drain hose The hose should not be allowed to hang loose from its connection to the unit Fasten the hose to a w...

Страница 13: ...nt of the farthest indoor unit from the main drain when installed indoor units are more than 3 2 You may need to install individual air vent to prevent water flow back at the top of each indoor unit drainpipe Hanger Main drainpipe Individual air vent Main air vent Centralized horizontal drainpipe more than 1 100 slope 550mm or less 1 1 5m ND 4HXEA_IM_E_33497A 1 indd 13 2011 03 08 오후 2 00 23 ...

Страница 14: ...stallation You should test the drainage after completing the installation Prepare a little water about 2 0 liters 1 Turn the cover drain pump then pull it out 2 Pour water into the indoor unit as shown in figure 3 Confirm that the water flows out through the drain hose 4 Reassemble the cover drain pump Testing the drainage If you do not pour water inside the water supply intake water may spill fro...

Страница 15: ...stalling the wired remote Control Indoor Unit 1 Outdoor Unit Indoor Unit 2 Indoor Unit 3 Wired Remote Control 220 240V h ELB Essential Installation TighteningTorque kgf cm M3 5 6 M3 5 8 10 M4 12 14 7 Using the correct tools connect the cables to the terminal board securely within the range of rated torque so the cable is firm and cannot be moved by external force or pressure Make sure the cables a...

Страница 16: ... 10 power drop among indoor units h X The capacity of ELB MCCB h Ai Sum of Rating currents of each indoor unit h Refer to each installation manual about the rating current of indoor unit Rating current Unit Model Ratingcurrent ND 4H 045 056 071 090 112 128 140 0 15A 0 15A 0 21A 0 30A 0 36A 0 36A 0 45A Selecting compressed ring terminal Silver solder Norminal dimensions forcable mm2 Norminal dimens...

Страница 17: ... Indoor unit1 ELB Coef 35 6 Lk ik 10 of input voltage V 1000 Ak n k 1 220 V 2 2 V 2 0 V 2 5 mm2 208 8 V Within 198V 242V 2 2 2 0 1 8 1 5 1 3 1 1 0 9 0 7 0 4 0 2 11 2 V it s okay 2 5 mm2 2 5 mm2 Installing with 1 sort wire 220 V 1 4 V 1 2 V 2 5 mm2 209 5 V Within 198V 242V 1 4 1 2 1 8 1 5 1 3 1 1 0 9 0 7 0 4 0 2 10 5 V it s okay 4 0 mm2 4 0 mm2 Installing with 2 different sort wire ND 4HXEA_IM_E_33...

Страница 18: ...13 SEG19 are not set as page option Set the SEG2 SEG6 SEG8 SEG12 as ON status and SEG14 18 SEG20 24 as OFF status SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 0 X X X X X 1 X X X X X SEG13 SEG14 SEG15 SEG16 SEG17 SEG18 SEG19 SEG20 SEG21 SEG22 SEG23 SEG24 2 X X X X X 3 X X X X X The procedure of option setting Settinganindoorunitaddressandinstallationoption Set the indoor unit add...

Страница 19: ...tation 6 Setting Fan mode Press Mode button to be changed to FAN mode in the ON status 7 Setting SEG9 SEG10 option Press Low Fan button to enter SEG9 value Press High Fan button to enter SEG10 value Each time you press the button will be selected in rotation 8 Setting Heat mode Press Mode button to be changed to HEAT mode in the ON status 9 Setting SEG11 SEG12 option Press Low Fan button to enter ...

Страница 20: ...gh Fan button to enter SEG22 value Each time you press the button will be selected in rotation 18 Setting Heat mode Press Mode button to be change to HEAT mode in the OFF status 19 Setting SEG23 SEG24 mode Press Low Fan button to enter SEG23 value Press High Fan button to enter SEG24 value Each time you press the button will be selected in rotation SEG16 SEG18 SEG21 SEG23 SEG17 SEG20 SEG22 SEG24 S...

Страница 21: ...n Details Indication Details Indication Details Indication Details 0 A 0 No Main address 0 9 100 digit 0 9 10 digit 0 9 A unit digit 1 Main address setting mode Option SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 Explanation PAGE Setting RMC address Group channel 16 Group address Remote Controller Display Indication andDetails Indication Details Indication Details Indication Details Indication Details Indicat...

Страница 22: ...G1 SEG2 SEG3 SEG4 SEG5 SEG6 0 2 RESERVED Exterior temperature sensor Central control FAN RPM compensation SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 1 Drain pump Hot water heater Electronic heater Opening the electronic expansion valve Master Slave SEG13 SEG14 SEG15 SEG16 SEG17 SEG18 2 External control External control output S Plasma ion Buzzer Number of hours using filter SEG19 SEG20 SEG21 SEG22 SEG23 SEG...

Страница 23: ...8 Explanation PAGE Useofexternal control Setting the output of external control S Plasma ion Buzzer control Number of hours using filter Remote Controller Display Indication and Details Indication Details Indication Details Indication Details Indication Details Indication Details Indication Details 2 0 Disuse 0 Thermo on 0 Disuse 0 Mixedoperation control1 Use buzzer 2 1000Hour 1 ON OFF Control 1 O...

Страница 24: ... Indication Details Indication Details Indication Details 0 D Option mode 0 F Tens digit ofSEG 0 9 Unitdigit ofSEG 0 9 The changed value 0 F When changing a digit of an indoor unit address setting option set the SEG3 as A When changing a digit of indoor unit installation option set the SEG3 as 2 Ex When setting the buzzer control into disuse status Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 Explanation ...

Страница 25: ...oor temperature sensor Error of the condensor temperature sensor Error of the discharge temperature sensor X X No communication for 2 minutes between indoor and outdoor unit communication error for more than 2minutes X X Error of outdoor unit X Detection of the float switch X X EEPROM error X EEPROM option error Mixed operation error X X X If you turn off the air conditioner when the LED is flicke...

Страница 26: ...26 Memo ND 4HXEA_IM_E_33497A 1 indd 26 2011 03 08 오후 2 28 13 ...

Страница 27: ...27 ND 4HXEA_IM_E_33497A 1 indd 27 2011 03 08 오후 2 28 13 ...

Страница 28: ... EEE Yönetmeliğine Uygundur This EEE is compliant with RoHS ND 4HXEA_IM_E_33497A 1 indd 26 2011 03 08 오후 2 00 34 ...

Отзывы: