English 23
Installation instructions
Supplied parts
The following parts make up the LP conversion kit:
ORIFICES/ORIFICES/ORIFICIOS
LR(WHT)
LF(WHT)
RF(RED)
RR(YEL)
CENTER
Out(WHT)
In(GRAY)
DG69-00399C
DG96-00686C
(ASSY NOZZLE-KIT)
NA30N9755T*/NA36N9755T*
The all orifices’ positions are marked on the provided sheet. The spud in the
pressure regulator is factory-installed for Natural Gas (NG) use. LP conversion
requires spud removal and reinstallation for LP use.
BURNER ORIFICE SIZES AND OUTPUT RATINGS
(LP Gas [Propane] 10 in WCP)
Burner Location
BTU Rate
Orifice size [mm]
RF
11,500
1.04
LF
7,500
0.83
RR
4,000
0.62
LR
7,500
0.83
Center
16,500
In: 0.46 / Out: 0.83 (2 pcs)
BURNER ORIFICE SIZES AND OUTPUT RATINGS
(Natural Gas 5 in WCP)
Burner Location
BTU Rate
Orifice size [mm]
RF
13,000
1.64
LF
9,500
1.40
RR
5,000
1.01
LR
9,500
1.40
Center
22,000
In: 0.85 / Out: 1.36 (2 pcs)
NOTE
115
Orifice markings:
115 – Denotes 1.15 mm orifice size opening.
Install_NA36N9755TM_DG68-01092A-02_EN+MES+CFR.indb 23
10/24/2018 4:47:24 PM