background image

E-

19

ENGLISH

Locking the Part of the Wired remote controller

To prevent the wired remote controller from children and 

changing settings unwillingly, you can lock some functions of 

wired remote controller.

1

Press the 

 button for 3 seconds to enter the setup 

mode.

Result:

 

 

The wired remote controller will enter the setup 

mode and the menu will  

display  .

2

Press the 

 buttons and select menu  .

Result:

 

   Each time the 

 buttons are pressed, 

menu number increases by 1.

 

   Press the 

 button to enter the lock setup 

mode.

Note 

 

Press the 

 button to cancel the setting.

3

Using the 

 buttons, you can set the lock setting 

value of the 

 buttons.

Result:

 

   Lock setting value

- 0: Cancel lock 

- 1: Set lock

 

   Press the 

 button after setting.

Press the 

 button to complete the part lock settings. 

Result:

 

   Changed settings will be applied.

 

     will be displayed when the lock function is 

set.

Note 

 

Press the 

 button to cancel the setting.

5

Press the 

 button. 

Result:

 

Menu selection display will end.

Note

 

  

If the centralized control is set, you cannot use the 

part lock function.

 

  

You cannot use the part lock function when Lock all 

is set.

 

  

Part Lock function can be applied to 

,  

, and 

 buttons only.

On/off 

button

Temperature 

setting button

Mode button

Fan speed button

MWR-WH02_IB_E_33323-1.indd   19

2011-01-10   오후 1:13:50

Содержание MWR-WH02

Страница 1: ...emote Control MWR WH02 DB98 33323A 1 I F S E P G Ne Po Hu A R D Air Conditioner user manual imagine the possibilities ThankyouforpurchasingthisSamsungproduct MWR WH02_IB_E_33323 1 indd 21 2011 01 10 오후 1 13 51 ...

Страница 2: ... the remote controller with wet hands Do not install the remote controller in a location where it will come into contact with the combustible gases machine oil sulphide gas etc Do not press buttons with a pointed thing Do not pull or bend the wired remote controller cable excessively Do not use this wired remote controller for other purpose Do not spray an insecticide or other combustible things o...

Страница 3: ...Heating Mode 10 Selecting the Quiet Mode 11 Selecting the Sleep Mode 12 Adjusting the Air Swing Direction 13 Checking the Room Temperature 14 Locking the Wired remote controller 14 Setting the On Timer 15 Setting the Off Timer 16 Setting the Auto Stop Function 17 Setting the Temperature Limits 18 Locking the Parts of the Wired remote controller 19 MWR WH02_IB_E_33323 1 indd 3 2011 01 10 오후 1 13 27...

Страница 4: ...an the filter and turn off the display when the button are pressed will be displayed if you press the button of the function that the indoor unit does not support If the indoor unit does not support Set temperature display Set temperature is not displayed on remote controller ON OFF timer Error Status display Operation mode display Fan speed Air swing display Special function display ON OFF time s...

Страница 5: ...ormation on using your wired remote controller Please take the time to read them as they will help you take full advantage of the unit s features In the manual you will find a series of step by step procedures for each function available The illustrations in the step by step procedures use 3 different symbols PRESS PUSH HOLD DOWN MWR WH02_IB_E_33323 1 indd 5 2011 01 10 오후 1 13 28 ...

Страница 6: ... the AUTO mode press the button until Auto is displayed on the remote controller Result The air conditioner will operate in auto mode The auto fan speed will be selected automatically in auto mode You cannot control the fan speed 3 To adjust the temperature press the buttons The temperature can be set between 18 C 65 F and 30 C 86 F Result The temperature will be adjusted by 1 C 1 F when the butto...

Страница 7: ...utes 2 To select the COOL mode press the button until Cool is displayed on the remote controller Result The air conditioner will operate in cooling mode 3 To adjust the temperature press the buttons The temperature can be set between 18 C 65 F and 30 C 86 F Result The temperature will be adjusted by 1 C 1 F when the buttons are pressed 4 Select the fan speed by pressing the button Result Each time...

Страница 8: ...r will start up after 3 minutes 2 To select the DRY mode press the button until Dry is displayed on the remote controller Result The air conditioner will operate in dry mode The Auto fan speed will be selected automatically in the dry mode You cannot control the fan speed 3 To adjust the temperature press the buttons The temperature can be set between 18 C 65 F and 30 C 86 F Result The temperature...

Страница 9: ... after being Plugged in Stopped The air conditioner will start up after 3 minutes 2 To select the FAN mode press the button until Fan is displayed on the remote controller Result The air conditioner will operate in fan mode You cannot adjust the temperature in fan mode 3 Select the fan speed by pressing the button Result Each time the button is pressed fan speed will change in the following order ...

Страница 10: ... conditioner will start heating if the set temperature is higher than the room temperature The fan will operate even if the set temperature is lower than the room temperature 4 Select the fan speed by pressing the button Result Each time the button is pressed fan speed will change in the following order Low Med High Auto 5 To adjust the air swing direction refer to page 13 Note Afterstartingheatin...

Страница 11: ...h the most recently used mode 2 Select the desired operation mode by pressing the button 3 Press the button to select the Quiet mode Result The air conditioner will operate in quiet mode Operating noise will be reduced Note Press the button again to exit the quiet mode Note If the indoor unit does not support Quiet mode will be displayed when you press the button If you press the button in fan mod...

Страница 12: ...sired operation mode by pressing the button Note Only cooling and heating mode support the sleep mode 3 Press the button to select the Sleep mode Result The air conditioner will operate in sleep mode The air conditioner will gradually raise or lower the set temperature internally and eventually turn off automatically after 6 hours Note Press the button again to exit the sleep mode Note If the indo...

Страница 13: ...ency of the air conditioner can be increased 1 Press the button Result The blade will start swinging up and down Press the button again to stop the blade from swinging and set the blade to the desired position Note The air swing direction cannot be set on duct type indoor units will be displayed when the button is pressed MWR WH02_IB_E_33323 1 indd 13 2011 01 10 오후 1 13 41 ...

Страница 14: ...lation location of the remote controller Locking theWired remote controller Lock the wired remote controller to prevent it from children and changing the settings unwillingly 1 Press the button for 3 seconds Result will be displayed and the wired remote controller is locked When the wired remote controller is locked you cannot control the air conditioner by the wired remote controller Note Press t...

Страница 15: ... in 1 hour unit each time you press the button 3 Press button to set the time Result On indicator will stop blink When the pre set time passes indoor unit will turn on automatically Operation mode temperature fan speed air flow direction will be same as the most recent operation settings Note When the On Timer is set you can cancel it by pressing the button When the centralized control is set Time...

Страница 16: ... you press the button 3 24 hours Time will be changed in 1 hour unit each time you press the button 3 Press button to set the time Result Off indicator will stop blink When the pre set time passes indoor unit will turn off automatically Note When the Off Timer is set you can cancel it by pressing the button When the centralized control is set Timer will not be effective Timer will be canceled if y...

Страница 17: ...r the Auto Stop setup mode 2 Press the buttons to set the auto stop time Result Time is adjusted by 1 hour when the buttons are pressed The default time setting is 0 The auto stop time can be set between 0 and 12 hours If you select 0 auto stop function will be canceled 3 Press the button to complete the auto stop function Result Auto stop function is set Note To cancel the auto stop function pres...

Страница 18: ...by the button and set the upper limit Each time the buttons are pressed the temperature is increased decreased by 1 C 1 F Press the button after setting Press the button to cancel the temperature limits setup 4 Press the button to complete the temperature limit settings Result The temperature setting will be restricted by the set lower upper temperature limit Note Press the button to cancel the se...

Страница 19: ...ncel the setting 3 Using the buttons you can set the lock setting value of the buttons Result Lock setting value 0 Cancel lock 1 Set lock Press the button after setting 4 Press the button to complete the part lock settings Result Changed settings will be applied will be displayed when the lock function is set Note Press the button to cancel the setting 5 Press the button Result Menu selection disp...

Страница 20: ...MWR WH02_IB_E_33323 1 indd 20 2011 01 10 오후 1 13 51 ...

Отзывы: