background image

Samsung Electronics

5-4 High Voltage Capacitor

5-5 High Voltage Diode

5-6 Main Relay and Power Control Relay

5-7 Adjustment of Primary Switch, Door Sensing Switch and Monitor Switch

5-2

1. Check continuity of the capacitor with the meter set at the highest resistance scale.
2. Once the capacitor is charged, a normal capacitor shows continuity for a short time, and then indicates 9M

Ω.

3. A shorted capacitor will show continuous continuity.
4. An open capacitor will show constant 9M

Ω.

5. Resistance between each terminal and chassis should read infinite.

1. Isolate the diode from the circuit by disconnecting its leads.
2. With the ohm-meter set at the highest resistance scale, measure across the diode terminals. Reverse the

meter leads and read the resistance. A meter with 6V, 9V or higher voltage batteries should be used to
check the front-to back resistance of the diode (otherwise an infinite resistance may be read in both
directions). The resistance of a normal diode will be infinite in one direction and several hundred K

in

the other direction.

1. When mounting Primary switch and Interlock

Monitor switch to Latch Body, consult the
figure.

2. No specific adjustment during installation of

Primary switch and Monitor switch to the latch
body is necessary.

3. When mounting the Latch Body to the oven

assembly, adjust the Latch Body by moving it so
that the oven door will not have any play in it.
Check for play in the door by pulling the door
assembly. Make sure that the latch keys move
smoothly after adjustment is completed.
Completely tighten the screws holding the Latch
Body to  the oven assembly.

4. Reconnect to Monitor switch and check the

continuity of the monitor circuit and all latch
switches again by following the components test
procedures.

5. Confirm that the gap between the switch

housing and the switch actuator is no more than
0.5mm when door is closed.

1. The relays are located on the PCB Ass'y.  Isolate them from the main circuit by disconnecting the leads. 
2. Operate the microwave oven with a water load in the oven. Set the power level set to high.
3. Check continuity between terminals of the relays after the start pad is pressed.

Precaution!

For continued protection against radiation hazard, replace parts in accordance with the wiring diagram and be sure to use the
correct part number for the following switches: Primary interlock and door sensing switches, and the interlock monitor switch
(replace all together). Then follow the adjustment procedures below. After repair and adjustment, be sure to check the continuity
of all interlock switches and the interlock monitor switch.

Alignment and Adjustments

Door Open

Door Closed

Primary switch

0

Monitor switch (COM-NC)

0

Door Sensing S/W

0

Primary Interlock Switch

Lever Door

Body Latch

Door Sensing
Switch

Interlock Monitor
Switch

Содержание MW4592W

Страница 1: ...RVICEManual MICROWAVE OVEN CONTENTS 1 Precaution 2 Specifications 3 Operating Instructions 4 Disassembly and Reassembly 5 Alignment and Adjustments 6 Troubleshooting 7 Exploded Views and Parts List 8...

Страница 2: ...or inspection within the microwave generating compartments check the magnetron wave guide or transmission line and cavity for proper alignment integrity and connections d Any defective or misadjusted...

Страница 3: ...icians should remove their watches while repairing an MWO 11 To avoid any possible radiation hazard replace parts in accordance with the wiring diagram Also use only the exact replacements for the fol...

Страница 4: ...ve terminal of the high voltage capacitor to the oven chassis Use a screwdriver 3 High voltage is maintained within specified limits by close tolerance safety related components and adjustments If the...

Страница 5: ...93G ITEM TIMER 99 MINUTES 99 SECONDS CONTROLS 10 POWER LEVELS INCLUDING DEFROST POWER SOURCE 120V 60HZ AC POWER CONSUMPTION MICROWAVE 1 450W OUTPUT POWER 700 Watts OPERATING FREQUENCY 2 450MHz OUTSIDE...

Страница 6: ...to level other than high Clock Sets current time Start Pause Canel Press to pause oven or correct a mistake Kitchen Timer Sound Button Auto Reheat Auto Defrost Start One Minute Pause Cancel 3 2 1 Cloc...

Страница 7: ...or it may be damaged NOTE2 When replacing the magnetron be sure to remount the magnetron gasket in the correct position and make sure the gasket is in good condition 1 Discharge the high voltage capa...

Страница 8: ...a thin metal plate between Door E and Door A until you hear the tick sound Insertion depth of the thin metal plate should be 0 5mm or less Insert flat screwdriver into the gap between Door A and Door...

Страница 9: ...efective component parts of the door reassemble it and follow the instructions below for proper installation and adjustment so as to prevent an excessive microwave leakage 1 When mounting the door to...

Страница 10: ...econnecting the FPC connector make sure that the holes on the connector are properly engaged with the hooks on the Plastic Fastener 1 Window display should not be disassembled as its mounting tabs wil...

Страница 11: ...al and magnetron case should read open 1 The low voltage transformer is located on the control circuit board 2 Remove the low voltage transformer from the PCB Ass y and check continuity 3 Normal resis...

Страница 12: ...ssembly adjust the Latch Body by moving it so that the oven door will not have any play in it Check for play in the door by pulling the door assembly Make sure that the latch keys move smoothly after...

Страница 13: ...tir the water again with the thermometer and measure the temperature T2 5 Subtract T1 from T2 This will give you the water temperature rise T 6 The output power is obtained by the following formula 7...

Страница 14: ...of a radiarion preventing device make a repair record for the measured values and keep the data 2 If the radiation leakage is more than 5 mW cm2 after determining that all parts are in good condition...

Страница 15: ...sensing switch 3 Defective monitor switch NOTE1 4 Shorted HVCapacitor 5 Shorted HVTransformer NOTE2 NOTE 1 All of these switches must be replaced at the same time refer to adjustment instructions Che...

Страница 16: ...1 Loose fan and fan motor Tighten screws of fan motor 2 Loose screws on H V Transformer Tighten screws of H V Transformer 3 Shorted H V Diode Replace H V Diode Turntable motor does not rotate 1 Open o...

Страница 17: ...nics 7 Exploded Views and Parts List 7 1 Exploded Views 7 1 M1 M2 M21 M22 M25 M26 M11 M13 M14 M15 M12 M16 M17 M18 M19 M20 M3 M4 M5 M6 M7 M8 M9 M10 B1 B2 B2 B4 B3 M23 C1 C2 C3 C4 C5 C6 C7 M24 D1 D2 D3...

Страница 18: ...H10 T2 5 W31X100 5 12G NTR 3RD W 1 M12 DE26 10156A TRANS H V SHV 4593UC 120V 2015V 3 10V 60 1 M13 2501 001112 C OIL 800nF 2 1KV BK 54x35x70 20mm 1 M14 DE61 50106A BRACKET HVC SECC T0 8 W31 L125 8 1 M1...

Страница 19: ...t Ref No Parts No Description Specification Q ty Remarks C 1 DE66 20275A BUTTON PUSH ABS HR0370U 9G P WHT W9501 3RD W S1 1 MW4592W C 1 DE66 20275C BUTTON PUSH ABS V0 GRY MW4593G 1 MW4593G C 2 DE61 700...

Страница 20: ...H SCREW A 2S 4X12 TOOTHED 1 P CORD DE60 10082H SCREW A 2S 4X12 TOOTHED 1 PCB GND DE60 10098A SCREW ASSY TAP TITE PH TC M4X8 SWRCH18A ZPC2 GLD W 2 G MOTOR DE60 10098A SCREW ASSY TAP TITE PH TC M4X8 SWR...

Страница 21: ...8 P C B Diagrams 8 1 P C B Diagrams Samsung Electronics 8 1...

Страница 22: ...2MM 2 R32 R33 P18 2001 000435 R CARBON 1MOHM 5 1 8W AA TP 1 8X3 2MM 1 R25 P19 2001 000515 R CARBON 220OHM 5 1 8W AA TP 1 8X3 2MM 1 R15 P20 2001 000577 R CARBON 2KOHM 5 1 8W AA TP 1 8X3 2MM 2 R05 R13...

Страница 23: ...ITION DOOR IS OPENED 120V15A PCB PATTERN WARNING NOTE CIRCUIT SHOWN WITH DOOR IS OPENED POSITION NOTE FOR SERVICE REPLACEMENT USE 16 GA 105 C THERMOPLASTIC COVERED WIRE EXCEPT FOR HIGH VOLTAGE LEADS O...

Отзывы: