ENGLISH-52
Troubleshooting tips
Water pump & Flow S/W
Display
Explanation
Flow S/W OFF error
In case of flow S/W OFF in 30sec during water pump signal is ON(Starting)
In case of flow S/W OFF in 15sec during water pump signal is ON (After starting)
Flow S/W ON error
In case of flow S/W ON in 10min during water pump signal is OFF
E911
•
Water pump ON ( Flow S/W off )
•
Water pump ON ( Flow S/W off ) : NOT enough water flow
Water flow < 16(7) LPM
E912
•
Water pump OFF ( Flow S/W on )
Water flow > 16(7) LPM