4-3-5 Reassembly Test
Samsung Electronics
4-3
1. Take out the glass tray and the guide roller from
the cavity.
2. Turn the oven upside down to replace the drive motor.
3. Remove a screw securing the drive motor cover
or disconnect the drive motor cover from base
plate by nipper.
4. Disconnect all the lead wires from the drive motor.
5. Remove screws securing the drive motor to the
cavity.
6. Remove the drive motor and the coupler.
7. When replacing the drive motor, be sure to
remount it in the correct position with the
coupler.
8. Connect all the leads to the drive motor.
9. Screw the drive motor cover to the base plate
with a screw driver.
1. Disconnect the oven from the power source.
2. When 20A fuse blows out by the operation of interlock monitor switch failure, replace the primary
interlock switch, door sensing switch, monitor switch and power relay.
3. When the above three switches operate properly, check if any other part such as the control circuit board,
blower motor or high voltage transformer is defective.
4-4 Replacement of Fuse
4-5 Replacement of Drive Motor
Disassembly and Reassembly
Screw
Drive Motor Cover
Base Plate
Thermo
Switch
Drive Motor
After replacement of the defective component parts of the door, reassemble it and follow the instructions below for proper
installation and adjustment so as to prevent an excessive microwave leakage.
1. When mounting the door to the oven, be sure to adjust the door parallel to the bottom line of the oven
face plate by moving the upper hinge and lower hinge in the direction necessary for proper alignment.
2. Adjust so that the door has no play between the inner door surface and oven front surface. If the door
assembly is not mounted properly, microwave energy may leak from the space between the door and
oven.
3. Do the microwave leakage test.