Samsung ME179KFETSR/AA Скачать руководство пользователя страница 3

3

General information

IMPORTANT SAFETY INSTRUCTIONS

This product requires a three-prong grounded 

outlet. The installer must perform a ground 

continuity check on the power outlet box before 

beginning the installation to insure that the 

outlet box is properly grounded. If not properly 

grounded, or if the outlet box does not meet 

electrical requirements noted (under ELECTRICAL 

REQUIREMENTS), a qualified electrician should be 

employed to correct any deficiencies.

Insure proper
ground exists
before use

CAUTION: For personal 

safety, remove house 

fuse or open circuit 

breaker before 

beginning installation 

to avoid severe or fatal 

shock injury.

CAUTION: For personal safety, the mounting 

surface must be capable of supporting the 

cabinet load and the added weight of this 69 

pound product, plus additional oven loads 

of up to 50 pounds or a total weight of 109 

pounds.

CAUTION: For personal safety, this product 

cannot be installed in cabinet arrangements 

such as an island or a peninsula. It must be 

mounted to BOTH a top cabinet AND a wall.

NOTE: For easier installation and personal 

safety, it is recommended that two people 

install this product.

IMPORTANT – PLEASE READ CAREFULLY. 

FOR PERSONAL SAFETY, THIS APPLIANCE 

MUST BE PROPERLY GROUNDED TO AVOID 

SEVERE OR FATAL SHOCK.

Insure proper
ground exists
before use

Insure proper 

ground exists 

before use.

The power cord of this 

appliance is equipped 

with a three-prong 

(grounding) plug which 

mates with a standard 

three-prong (grounding) 

wall receptacle to 

minimize the possibility 

of electric shock hazard 

from this appliance.

You should have the wall receptacle and circuit 

checked by a qualified electrician to make sure 

the receptacle is properly grounded.

If you have a standard two-prong wall 

receptacle, it is very important to have it 

replaced with a properly grounded three-

prong wall receptacle, installed by a qualified 

electrician.

DO NOT, UNDER ANY CIRCUMSTANCES, CUT, 

DEFORM OR REMOVE ANY OF THE PRONGS 

FROM THE POWER CORD. DO NOT USE WITH 

AN EXTENSION CORD.

ELECTRICAL 

REQUIREMENTS

Product rating is 120 volts AC, 60 Hertz, 14.6 

amps and 1.75 kilowatts.This product must be 

connected to a supply circuit of the proper voltage 

and frequency. Wire size must conform to the 

requirements of the National Electrical Code or the 

prevailing local code for this kilowatt rating. The 

power supply cord and plug should be brought to a 

separate 15 ampere branch circuit single grounded 

outlet. The outlet box should be located in the 

cabinet above the microwave oven. The outlet box 

and supply circuit should be installed by a qualified 

electrician and conform to the National Electrical 

Code or the prevailing local code.

(Installation)ME179KFETSR_DE68-04129A_AA.indd   3

2012-05-21   �� 9:57:24

Содержание ME179KFETSR/AA

Страница 1: ...ese instructions with the Consumer Note to Consumer Keep these instructions for future reference Skill level Installation of this appliance requires basic mechanical and electrical skills Proper installation is the responsibility of the installer Product failure due to improper installation is not covered under the Warranty READ CAREFULLY KEEP THESE INSTRUCTIONS This manual is made with 100 recycl...

Страница 2: ...tion 12 B2 Installing the charcoal filter 13 C Outside back exhaust horizontal duct 14 C1 Adapting the microwave blower for outside back exhaust 14 3 Installation 15 A Preparing the rear wall for outside back exhaust 15 B Attach the mounting plate to the wall 15 C Use the top cabinet template to prepare the top cabinet 16 D Mount the microwave oven 16 E Connecting ductwork for outside top exhaust ...

Страница 3: ...HOCK Insure proper ground exists before use Insure proper ground exists before use The power cord of this appliance is equipped with a three prong grounding plug which mates with a standard three prong grounding wall receptacle to minimize the possibility of electric shock hazard from this appliance You should have the wall receptacle and circuit checked by a qualified electrician to make sure the...

Страница 4: ...ptor is used the bottom corners of the damper will have to be cut to fit using the tin snips in order to allow free movement of the damper OUTSIDE BACK EXHAUST EXAMPLE ONLY The following chart contains an example of one possible ductwork installation DUCT PIECES EQUIVALENT LENGTH x NUMBER USED EQUIVALENT LENGTH Wall Cap 40 ft x 1 40 ft 3 Ft Straight Duct 3 x 10 Rectangular 3 ft x 1 3 ft 90 Elbow 1...

Страница 5: ...ction of straight duct which is longer than their actual physical size When calculating the total duct length add the equivalent lengths of all transitions and adaptors plus the length of all straight duct sections The chart below shows you how to calculate total equivalent ductwork length using the equivalent length in feet of some typical ducts DUCT PIECES EQUIVALENT LENGTH x NUMBER USED EQUIVAL...

Страница 6: ...NS Wood Screws x 2 1 Template INSTALLATION INSTRUCTIONS Toggle Bolts and wing nuts 3 16 x 3 3 Template INSTALLATION INSTRUCTIONS Self aligning Machine Screws 28 x 3 3 You will find the installation hardware contained in a packet with the unit Check to make sure you have all these parts NOTE Some extra parts are included ADDITIONAL PARTS PART QUANTITY TOP CABINET TEMPLATE REAR WALL TEMPLATE Top Cab...

Страница 7: ...OTES The space between the cabinets must be 30 wide and free of obstructions This microwave oven is for installation over ranges up to 36 wide If you are going to vent your microwave oven to the outside see the Hood Exhaust Section for exhaust duct preparation If installing the microwave oven beneath smooth flat cabinets be careful to follow the instructions on the top cabinet template for power c...

Страница 8: ...e used as the rear wall template and for mounting 6 Replace the two screws you removed and carefully screw them back into the case DO NOT OVER TIGHTEN If you over tighten the screws you can strip the screws and damage the case B FINDING THE WALL STUDS Wall Studs Center Center Wall Studs 1 Find the studs using one of the following methods A Stud finder a magnetic device which locates nails OR B Use...

Страница 9: ...t with front overhang Draw a line on the back wall equal to the depth of the front overhang 30 to Cooktop Plate position beneath recessed bottom cabinet with front overhang 30 to Cooktop Draw a horizontal line to mark how far the inside of the front overhang descends below the cabinet Your cabinets may have decorative trim that interferes with the microwave installation Remove the decorative trim ...

Страница 10: ...on sharp edges 1 Draw a Horizontal line on the wall at the bottom of the Rear Wall Template 2 Drill holes for toggle bolts in 3 locations Hole A Hole B Hole C as shown in the illustration above If the location of a hole lines up with a stud drill a 3 16 hole for a wood screw You cannot use a toggle bolt to attach the wall plate to a stud NOTE DO NOT MOUNT THE PLATE AT THIS TIME 3 Holes A B and C a...

Страница 11: ...ust adaptor is shipped assembled and attached to the filler upper Select the type of ventilation required for your installation and proceed to that section A OUTSIDE TOP EXHAUST VERTICAL DUCT B RECIRCULATING NON VENTED DUCTLESS Adaptor in Place for Outside Top Exhaust Adaptor in Place for Outside Top Exhaust See page 12 See page 13 A Charcoal Filter Accessory Kit is required for the nonvented exha...

Страница 12: ...After you have installed the microwave you will need to open the top cabinet and adjust the exhaust adaptor so that you can connect it to the house duct For Front to Back Adjustment Slide the Exhaust Adaptor as Needed Blower Plate Back of Microwave Damper NOTE You must attach the house duct to the exhaust adaptor after installation is complete House Duct House Duct B RECIRCULATING NON VENTED DUCTL...

Страница 13: ...Roll After Roll Back of Microwave 5 Place the blower unit back into the opening CAUTION Do not pull or stretch the blower unit wiring Make sure the wires are not pinched 6 Secure the blower unit to the microwave with the screw B2 INSTALLING THE CHARCOAL FILTER 1 Remove the screws on the top of the grill using a 1 Phillips screwdriver 2 Open the door 3 Remove the grill Push the grill left and then ...

Страница 14: ...lower unit counterclockwise 180 Before Rotation After Rotation Back of Microwave Back of Microwave 6 Place the blower unit back into the opening AFTER Fan Blade Openings Facing Back End B End A CAUTION Do not pull or stretch the blower unit wiring Make sure the wires are not pinched NOTE The blower unit exhaust openings should match exhaust openings on the rear of microwave oven 7 Close the Blower...

Страница 15: ...al duct only B Attach Mounting Plate to Wall C Prepare Top Cabinet D Mount the Microwave Oven E Connecting Ductwork vertical duct only A PREPARING THE REAR WALL FOR OUTSIDE BACK EXHAUST You need to cut an opening in the rear wall for outside exhaust C L Read the instructions for outside back exhaust on the REAR WALL TEMPLATE Tape the REAR WALL TEMPLATE to the rear wall Cut the opening following th...

Страница 16: ...e instructions on the TOP CABINET TEMPLATE Tape it underneath the top cabinet Drill the holes following the instructions on the TOP CABINET TEMPLATE CAUTION Wear safety goggles when drilling holes in the cabinet bottom D MOUNT THE MICROWAVE OVEN FOR EASIER INSTALLATION AND PERSONAL SAFETY WE RECOMMEND THAT TWO PEOPLE INSTALL THIS MICROWAVE OVEN IMPORTANT Do not grip or use the handle during instal...

Страница 17: ... Shelf Equivalent to Depth of Cabinet Recess Cabinet Bottom Shelf Microwave Oven Top Cabinet Front Filler Block Self Aligning Screw 4 Attach the microwave oven to the top cabinet 5 Insert the 2 self aligning screws through the cabinet bottom shelf and filler block into the outer top cabinet of the unit Continue to support the unit until both screws are inserted and engaged at least two full turns ...

Страница 18: ...ce the house fuse or turn the breaker back on Insure proper ground exists before use 5 Plug the power cord into a dedicated 15 amp electrical outlet Insure proper ground exists before use Insure proper ground exists before use 6 Read the Owner s Manual 7 Keep installation instructions for the local inspector s use 4 BEFORE YOU USE YOUR MICROWAVE Installation ME179KFETSR_DE68 04129A_AA indd 18 2012...

Страница 19: ...19 Note Installation ME179KFETSR_DE68 04129A_AA indd 19 2012 05 21 9 57 31 ...

Страница 20: ...Code No DE68 04129A Installation ME179KFETSR_DE68 04129A_AA indd 20 2012 05 21 9 57 31 ...

Отзывы: