2. Specification
DVM S2 (460V)
Model Name
AM288BXVTJH/AA
Outdoor unit module 1
AM072BXVTJH/AA
Outdoor unit module 2
AM096BXVTJH/AA
Outdoor unit module 3
AM120BXVTJH/AA
Outdoor unit module 4
-
PowerSupply
Ø, #, V, Hz
3, 3, 460, 60
Mode
-
Heat Pump
Performance
TON
TON
24
Capacity(Nominal)
Cooling
Btu/h
288,000
Heating
Btu/h
324,000
Capacity(Rated)
Cooling
Btu/h
27
4
,000
Heating
Btu/h
30
8
,000
Maximum number of connectable indoor units
EA
49
Total capacity of the connected
IndoorUnits
Min.
Btu/h
144,000
Max.
Btu/h
374,400
Power
Current
MCA
A
-
MOP
A
-
Casing
Material
Body
-
GI Steel Plate
Base
-
GI Steel Plate
Heat
Exchanger
Type
-
Fin & Tube
Material
Fin
-
Al
Tube
-
Cu
Fin Treatment
-
Anti-corrosion
Compressor
Type
-
Inverter Scroll x 6
Output
kW x n
(4.
39
x 2) x 1 + (6.67 x 2) x 2
Model Name
-
(DS2GR7046FV* x 2) x 1 +
(DS4GR7066FV* x 2) x 2
Oil
Type
-
PVE
Initial
charge
cc x n
(900 x 2) x 1 + (1,100 x 2) x 2
fl oz x n
(30.4 x 2) x 1 + (37.2 x 2) x 2
Fan
Type
-
Propeller
Discharge direction
-
Top
Quantity
EA
6
Air Flow Rate
CFM
(
㎥
/min)
9,924 x 1 + 9,571 x 1 + 10,171 x 1
(281 x 1 + 271 x 1 + 288 x 1)
ExternalStatic
Pressure
Max.
㎜
Aq
-
Pa
-
in Wg (Pa)
-
Fan Motor
Type
-
BLDC Motor
Output
W x n
(620 x 2) x 3
Piping
Connections
LiquidPipe
Type
Braze connection
Φ
, inch (
㎜
)
3/4 (19.05)
Gas Pipe
Type
Braze connection
Φ
, inch (
㎜
)
1-3/8 (34.92)
HeatInsulation
-
Both liquid and gas pipes
Pipinglength
(ODU-IDU)
Max.
[Equiv.]
ft
656 [722]
Pipinglength
(1st Branch-IDU)
Max.
ft
295
Total pipinglength
(System)
Max.
ft
3,281
Level difference
(ODU in highest position)
Max.
ft
361
Level difference
(IDU in highest position)
Max.
ft
361
Level difference
(IDU-IDU)
Max.
ft
164