background image

Samsung Electronics

6-2

Parts

Cause

Diagnosis

Remedy

1) Too small

If a small amount of food is heated for a long time,

To increase the oven

a load

period of microwave may turn off during operation.

load, add a glass of

Microwave

water into the oven.

turns off
during cook-

2) Defective

Check to see if the magnetron thermal cutout switch is

Replace thermal cutout

ing cycle.

magnetron

activated at a temperature higher than 150˚C.

switch.

thermal
cutout S/W

Electric

Incomplete

Make sure that qrounding of the power supply cord has

Rewire.

shock is

qrounding

been done properly.

felt.

Door does

1) Broken door

Remove the cabinet for inspection.

Replace door hinges.

not operate

hinges

Check the door hinge.

properly

2) Missing or

Check if the screws are secured well to the door hinge.

Fasten or tighten.

loose screw

1) Defective

If the timer does not operate with 220~230V applied to the

Replace timer.

Timer does

timer motor

terminals, the timer motor amy be faulty.

not operate.

2) Defective

The lamp does not light.

Replace timer

contacts
of timer S/W

Cooking tray

1) Defective

Check to see if 21V exists at the motor terminals.

Replace drive motor.

does not

drive motor

If so, motor will be defective.

rotate.

1) Blocking of

Check if the air inlet or outlet ventilation is blocked

Keep a distance of

the ventilatior

by the wall or other objects.

100mm from the
wall or the objects.

Magnetron

2) Defective

If the fan motor does not operate with 220~230V applied

Replace fan motor.

thermal

fan motor

to the terminal, the motor may be faulty.

cutout
switch

3) Too small a

If a small amount of food is heated repeatedly over

To increase the oven

OFF

load or no

a long period of time, microwave turns off during

load, place a glass of

load

operation.

water into the oven.

6-1 Electrical Malfunction (Continved)

Troubleshooting

Содержание M1713

Страница 1: ...ERVICE Manual MICROWAVE OVEN CONTENTS 1 Precaution 2 Specifications 3 Operating Instructions 4 Disassembly and Reassembly 5 Alignment and Adjustments 6 Troubleshooting 7 Exploded Views and Parts List...

Страница 2: ...or inspection within the microwave generating compartments check the magnetron wave guide or transmission line and cavity for proper alignment integrity and connections d Any defective or misadjusted...

Страница 3: ...es interlock monitor switch 12 If the fuse is blown by the Interlock Monitor Switch Replace all of the following at the same time Primary door sensing switch and power relay as well as the Interlock M...

Страница 4: ...oltage capacitor to to the oven chassis Use a screwdriver 3 High voltage is maintained within specified limits by close tolerance safety related components and adjustments If the high voltage exceeds...

Страница 5: ...30V 50Hz SINGLE PHASE POWER CONSUMPTION 1 200W OUTPUT POWER 100W 800W OPERATING FREQUENCY 2450MHz TIMER 35 MINUTES COOLING METHOD AIR COOLING MAGNETRON OM75SH 31 ESST OUTSIDE DIMENSIONS 489 W x 351 D...

Страница 6: ...3 Operating Instructions 3 1 Control Panel 3 1 Samsung Electronics Instant Reheat Defrost Open Door Push Button...

Страница 7: ...to 100 maximum by turning COOKING POWER CONTROL knob 3 Set the time to 4 to 5 minutes by turing TIMER knob Important If any problem is experienced in the operation of the oven please refer to the sect...

Страница 8: ...80W WARM 100W 3 5 Adjusting the Cooking Time During Cooking Stopping the Cooking Adding Extra Time To stop the cooking Press Temporarily Open Door To resume cooking close the door Completely Turn the...

Страница 9: ...sure to remount the magnetron gasket in the correct position and make sure the gasket is in good condition 1 Discharge the high voltage capacitor 2 Disconnect all the leads 3 Remove the mounting bolt...

Страница 10: ...r Following the procedure as shown in the figure insert and bend a thin metal plate between Door E and Door A until you hear the tick sound Insertion depth of the thin metal plate should be 0 5mm or l...

Страница 11: ...rrect position 8 Connect all the leads to the drive motor 9 Screw the deive motor cover to the base plate with a screw driver 10 Remount the coupler in the correct position Disassembly ReaAssembly Scr...

Страница 12: ...4 A continuity check between each filament terminal and the magnetron case should read open 5 2 Magnetron 5 1 High Voltage Transformer Magnetron Antenn Cooling Fins Gasket Plate 5 Alignment and Adjust...

Страница 13: ...s and the interlock monitor switch all together Then follow the adjustment procedures below After repair and adjustment be sure to check the continuity of all interlock switches and the interlock moni...

Страница 14: ...e and time tests with accurate equipment 1 Fill the one liter glass vessel with one liter of water 2 Stir water in glass vessel with thermometer and record glass vessel s temperature as T1 10 1 C 3 Af...

Страница 15: ...of a radiarion preventing device make a repair record for the measured values and keep the data 2 If the radiation leakage is more than 4 mW cm2 after determining that all parts are in good condition...

Страница 16: ...use 2 Poor contact of Check continuity of power supply cord Also check Adjust or replace the power cord whether the power cord is securely wired power supply cord 3 Defective lamp The fan motor rotate...

Страница 17: ...screw 1 Defective If the timer does not operate with 220 230V applied to the Replace timer Timer does timer motor terminals the timer motor amy be faulty not operate 2 Defective The lamp does not lig...

Страница 18: ...heck the continuity of primary coil and secondary Replace the H V Trans coil If there is no continuity H V Transformer is H V Transformer former defective 7 Shorted H V Check the continuity of capacit...

Страница 19: ...7 1 7 Exploded Views and Parts List 7 1 Main Exploded View M1 M2 M3 M4 M30 M31 M5 M6 M7 M8 M13 M12 M9 B2 B3 B4 B1 M10 M21 M23 M24 M25 M26 M27 M28 M29 M15 M17 M16 M19 M18 M14 M22 M20 D6 D1 D2 D3 D5 D4...

Страница 20: ...1 M15 DE26 10159A TRANS H V SHV 173EC 230V 2190V 3 40V 50H 1 M16 DE61 50106A BRACKET HVC SECC T0 8 W31 L125 8 1 M17 2501 001110 C OIL 860nF 2 1KV BK 54x35x75 20mm 1 M18 DE59 40001A DIODE H V HVR 1X 3...

Страница 21: ...E66 20281A BUTTON PUSH ABS 15g T2x37x86 WHT 3RD W B D 1 C 2 DE61 70076A SPRING BUTTON HSWR PI0 6 1 C 3 DE64 10162A KNOB ABS WHT 3RD W 2 C 4 DE72 70214J CONTROL PANEL D ABS M1713 XEU WHITE 3RD S2 1 C 5...

Страница 22: ...2 TOOTHED 3 B PLATE DE60 10082H SCREW A 2S 4X12 TOOTHED 1 C BLOWER DE60 10082H SCREW A 2S 4X12 TOOTHED 2 C BOX DE60 10082H SCREW A 2S 4X12 TOOTHED 4 O PANEL DE60 10098A SCREW ASSY TAP TITE PH TC M4X8...

Страница 23: ...ESISTOR VPC S W MONITOR FUSE 1 6A WHT COM COM NC NO PIN BLU BLU WHT WHT PIN MONITOR S W BRN 230V H V TRANS H V FUSE 0 75A H V C 0 91uF H V D MAGNETRON F FA FUSE 250V10A 0 1 uF 1 mH 500K 2200pF 2200pF...

Отзывы: