English
_19
●
INST
ALLA
TION & CONNECTION
Communication Protocol DIP Switch Settings (SW2)
Coaxial communication automatically detects signals, and so does not require a separate
communication setup process.
SW2 Pin No.
Purpose
1~4
Protocol Settings
5~6
Baud Rate Settings
7
Response Mode Settings
8
Termination Settings
Protocol Settings
Select a communication protocol for the camera.
No.
Protocol
SW2-#1
SW2-#2
SW2-#3
SW2-#4
1
AUTO DETECT
OFF
OFF
OFF
OFF
2
Samsung-T
OFF
OFF
OFF
ON
3
Pelco-D
OFF
OFF
ON
OFF
4
Pelco-P
OFF
OFF
ON
ON
5
Samsung-E
OFF
ON
OFF
OFF
6
Panasonic
OFF
ON
OFF
ON
7
Vicon
OFF
ON
ON
OFF
8
Honeywell
OFF
ON
ON
ON
9
AD
ON
OFF
OFF
OFF
10
GE
ON
OFF
OFF
ON
11
BOSCH
ON
OFF
ON
OFF
12
Reserved
ON
OFF
ON
ON
13
Reserved
ON
ON
OFF
OFF
14
Reserved
ON
ON
OFF
ON
15
Reserved
ON
ON
ON
OFF
16
Reserved
ON
ON
ON
ON
ON
ON
OFF