Level 3 Repair
Distribution, transmission, or infringement of any content or data from this document without Samsung’s written authorization is strictly prohibited.
Confidential and proprietary-the contents in this service guide subject to change without prior notice.
8-61
※
CAUTION
Temperature/Humidity sensor should not be directly exposed to the heat-gun when you replace
USB connector, because excessive heat can cause abnormal operation of the sensor. The
temperature that Temperature/Humidity sensor sees should not exceed 260°C. Use proper heat-
shielding material to protect Temperature/Humidity sensor.
※
Temp/Humi Sensor After Repair
1) Keypad : press *#0*#
2) Select "Sensor"
3) Select "Temp-Humid"
4) Read the COMP data (ignore the RAW data)