Level 3 Repair
Distribution, transmission, or infringement of any content or data from this document without Samsung’s written authorization is strictly prohibited.
Confidential and proprietary-the contents in this service guide subject to change without prior notice.
8-59
8. TEMP/Humidity sensor
Check the Voltage
VCC_1.8V_AP = 1.8V
Abnormal Temp/Humi Sensor part
END
No
Yes
Check the Voltage
R822 = 1.8V
R823 = 1.8V
No
Yes
Temp/Humi Sensor operate
correctly?
No
Yes
Reconnect SUB PBA and main PBA or
resolider U600
Resolder U805 or heat over U600
Change SUB PBA
Yes