Installation
Installation
English
20
• Gas dryers are equipped with a burner
vent for use with natural gas. If you
plan to use your dryer with LP (liquid
propane) gas, it must be converted
for safe and proper performance by
a qualified service technician. (
LNG
models only
)
You must check the burner of your
model and use the proper LP Kit
accordingly. To check the detail
information of the burner, open the
door and check the rating label location
on the door frame.
- 20,000 BTU: LPKIT-4/XAA (DC98-
04114A)
- 22,000 BTU: LPKIT-3/XAA (DC99-
00792A)
• A 1/2” (1.27 cm) gas supply line is
recommended and must be reduced to
connect to the 3/8” (1 cm) gas line on
your dryer. The National Fuel Gas Code
requires that an accessible, approved
manual gas shut-off valve be installed
within 6” of your dryer.
• Gas dryers installed in residential
garages must be raised 18 inches (46
cm) above the floor.
• Additionally, a 1/8” (0.3 cm) N.P.T.
(National Pipe Thread) plugged tapping,
accessible for test gauge connection,
must be installed immediately upstream
of your dryer’s gas supply connection.
• Your dryer must be disconnected from
the gas supply pipe system during any
pressure testing of the system.
• Do not reuse old flexible metal gas
lines. Flexible gas lines must be
designed and certified by the standard
for connectors for Gas Appliances, ANSI
Z21.24 • CSA 6.10.
NOTE
• Your dryer uses an automatic ignition
system to ignite the burner. There is no
constant burning pilot.
• Any pipe joint compound used must be
resistant to the action of any liquefied
petroleum gas.
• As a courtesy, most local gas utilities
will inspect a gas appliance installation.
Commonwealth of Massachusetts
installation instructions
Your dryer must be installed by a licensed
plumber or gas fitter. A “T” handle manual
gas valve must be installed in the gas
supply line to your dryer. If a flexible gas
connector is used to install your dryer, the
connector can be no longer than 3’ (36”).
WARNING
• Gas leaks may occur in your system,
creating a dangerous situation.
• Gas leaks may not be detected by smell
alone.
• Gas suppliers recommend you purchase
and install a UL-approved gas detector.
• Install and use in accordance with the
manufacturer’s instructions.
FlexDry_DM9600M_DC68-03381H-07_EN.indd 20
2019-06-03 2:57:17
Содержание FlexDry DVG55M9600W
Страница 1: ...FlexDry User manual DV 55M9600 FlexDry_DM9600M_DC68 03381H 07_EN indd 1 2019 06 03 2 57 12 ...
Страница 73: ...Memo FlexDry_DM9600M_DC68 03381H 07_EN indd 73 2019 06 03 2 57 28 ...
Страница 74: ...Memo FlexDry_DM9600M_DC68 03381H 07_EN indd 74 2019 06 03 2 57 28 ...
Страница 75: ...Memo FlexDry_DM9600M_DC68 03381H 07_EN indd 75 2019 06 03 2 57 28 ...
Страница 77: ...FlexDry Manuel d utilisation DV 55M9600 FlexDry_DM9600M_DC68 03381H 07_CFR indd 1 2019 06 03 2 56 03 ...
Страница 149: ...Mémo FlexDry_DM9600M_DC68 03381H 07_CFR indd 73 2019 06 03 2 56 19 ...
Страница 150: ...Mémo FlexDry_DM9600M_DC68 03381H 07_CFR indd 74 2019 06 03 2 56 19 ...
Страница 151: ...Mémo FlexDry_DM9600M_DC68 03381H 07_CFR indd 75 2019 06 03 2 56 19 ...
Страница 153: ...FlexDry Manual del usuario DV 55M9600 FlexDry_DM9600M_DC68 03381H 07_MES indd 1 2019 06 03 2 56 37 ...
Страница 225: ...Notas FlexDry_DM9600M_DC68 03381H 07_MES indd 73 2019 06 03 2 56 53 ...
Страница 226: ...Notas FlexDry_DM9600M_DC68 03381H 07_MES indd 74 2019 06 03 2 56 53 ...
Страница 227: ...Notas FlexDry_DM9600M_DC68 03381H 07_MES indd 75 2019 06 03 2 56 53 ...