instAllinG thE Anti-tiP DEViCE

WARNING

 

WARNING

 To reduce the risk of tipping, the appliance must be secured by properly 

installing the Anti-Tip device packed with the appliance.
•  Refer to the installation instructions supplied with the bracket.
•  Unless properly installed, the range could be tipped by stepping or sitting on the door. Injury may 

result from spilled hot  liquids or from the range itself.

Anti-Tip 
bracket

Screw must enter wood or 

concrete

*approximately 

21/32”(16.5mm)

*NOTE:

 To install Anti-Tip bracket, 

release the leveling leg. A minimum 
clearance of 21/32”(16.5mm) is required 
between the range bottom and the 
kitchen floor.

1. Locate the bracket using the template

The Anti-Tip bracket is packaged with a template. The instructions include information necessary to 
complete the installation. Read and follow the instructions on the sheet (template) for range installation.

2. Level the range

Level the range by adjusting the leveling legs with a wrench.

Lower range

Raise range

Leveling leg

Installation-USA DG68-00108E-01_EN.indd   11

2011-03-18   �� 4:06:29

Содержание FE-N500WX

Страница 1: ...at www samsung com register 1 800 SAMSUNG 726 7864 Electric Range installation manual ENGLISH This manual is made with 100 recycled paper F T Q 3 8 6 F T Q 3 5 2 F C Q 3 2 1 F T Q 3 8 7 F T Q 3 5 3 F...

Страница 2: ...lements should be avoided The range should not be placed on a base FOR YOUR SAFETY WARNING WARNING If the information in this manual is not followed exactly a fire or electrical shock may result causi...

Страница 3: ...appliance PREPARE TOOLS PARTS What tools you will need Drill Adjustable Wrench Pliers 1 4 Nut Driver Phillips Screwdriver Flat Screwdriver Pencil Level What s included with your range Template Anti T...

Страница 4: ...electrical outlet area Minimum dimensions IMPORTANTTo eliminate the risk of burns or fire caused by reaching over heated surface units cabinet storage space located above the surface units should be a...

Страница 5: ...cy MA 02269 Effective January 1 1996 the National Electrical Code requires that new construction not existing utilize a 4 conductor connection to an electric range When installing an electric range in...

Страница 6: ...n be accessible Access cover Terminal block Specified power supply cord kit rating Range rating watts Specified rating of power supply cord kit amperes Diameter inches of range connection opening 120...

Страница 7: ...e connected to the neutral terminal located in the center of the terminal block The power leads must be connected to the lower left and the lower right terminals of the terminal block 1 Remove the 3 l...

Страница 8: ...ain them 2 Cut and discard the ground strap Do not discard any screws 3 Insert the one ground screw into the power cord ground wire terminal ring through the ground plate and into the frame of the ran...

Страница 9: ...orrect amperage and voltage to make the connection Connect wires according to Step 4 depending on the number of wires Wire used location and enclosure of splices etc must conform to good wiring practi...

Страница 10: ...earlier and secure it in place with the ground screw removed earlier 4 Insert the bare wire white neutral tip through the bottom center of the terminal block opening 5 Insert the two side bare wire t...

Страница 11: ...itself Anti Tip bracket Screw must enter wood or concrete approximately 21 32 16 5mm NOTE To install Anti Tip bracket release the leveling leg A minimum clearance of 21 32 16 5mm is required between t...

Страница 12: ...e enough to the opening to plug into the receptacle Slide range into position insuring that the rear left or rear right leg slides under the Anti Tip bracket The range will sit 0 away from the back wa...

Отзывы: