English
41
Maint
enanc
e
Nozzles
To prevent the nozzles from being clogged or if the nozzles are clogged, remove and clean
each nozzle. Use caution when removing the nozzles as they may break.
Top nozzle
1.
Open the door, and then pull out the
upper rack. The top nozzle is visible on
the top.
2.
Turn counter clockwise and remove the
nozzle cap
, and then remove the nozzle.
3.
Unclog and clean the nozzle.
4.
Reinsert the nozzle, and then tighten
the cap clockwise.
5.
Rotate the nozzle by hand to make sure
the nozzle is engaged correctly.
Upper nozzle
1.
Open the door, and then pull out the
upper rack to reveal the upper nozzle.
2.
Loosen and remove the nut, and then
remove the nozzle.
3.
Unclog and clean the nozzle.
4.
Reinsert the nozzle, and then tighten
the nut by hand.
5.
Rotate the nozzle by hand to make sure
the nozzle is engaged correctly.
DW5000C_DW80CB507012AA_DD68-00261A-00_EN_FULL.indd 41
2023-03-24 12:21:12