Installation requirements
English
13
Gas requirements
WARNING
• Use only natural or LP (liquid propane)
gases.
• The installation must be conformed with
local codes, or in the absence of local
codes, with the national fuel gas code,
ANSI Z223.1/NFPA 54, latest revision(for
the UNITED STATES), or with the natural
gas and propane installation code, CSA
B149.1(for Canada).
• Gas dryers are equipped with a burner
vent for use with natural gas. If you plan
to use your dryer with LP (liquid propane)
gas, it must be converted for safe and
proper performance by a qualified service
technician. (
LNG models only
)
You must check the burner of your model
and use the proper LP Kit accordingly. To
check the detail information of the burner,
open the door and check the rating label
location on the door frame.
- 20,000 BTU: LPKIT-4/XAA (DC98-04114A)
- 22,000 BTU: LPKIT-3/XAA (DC99-00792A)
• A
½
” (1.27 cm) gas supply line is
recommended and must be reduced
to connect to the ⅜” (1 cm) gas line on
your dryer. The National Fuel Gas Code
requires that an accessible, approved
manual gas shut-off valve be installed
within 6” of your dryer.
• Gas dryers installed in residential garages
must be raised 18 inches (46 cm) above
the floor.
• Additionally, a ⅛” (0.3 cm) N.P.T. (National
Pipe Thread) plugged tapping, accessible
for test gauge connection, must be
installed immediately upstream of your
dryer’s gas supply connection.
• Your dryer must be disconnected from
the gas supply pipe system during any
pressure testing of the system.
• Do not reuse old flexible metal gas lines.
Flexible gas lines must be designed and
certified by the standard for connectors
for Gas Appliances, ANSI Z21.24 • CSA
6.10.
NOTE
• Your dryer uses an automatic ignition
system to ignite the burner. There is no
constant burning pilot.
• Any pipe joint compound used must be
resistant to the action of any liquefied
petroleum gas.
• As a courtesy, most local gas utilities will
inspect a gas appliance installation.
Commonwealth of Massachusetts
installation instructions
Your dryer must be installed by a licensed
plumber or gas fitter. A “T” handle manual
gas valve must be installed in the gas supply
line to your dryer. If a flexible gas connector
is used to install your dryer, the connector
can be no longer than 3’ (36”).
WARNING
• Gas leaks may occur in your system,
creating a dangerous situation.
• Gas leaks may not be detected by smell
alone.
• Gas suppliers recommend you purchase
and install a UL-approved gas detector.
• Install and use in accordance with the
manufacturer’s instructions.
DV8650M_DC68-03170X-05_EN.indd 13
2019-06-03 5:08:08
Содержание DVE52M8650 Series
Страница 1: ...Dryer User manual DVE G 52M8650 DV8650M_DC68 03170X 05_EN indd 1 2019 06 03 5 08 07 ...
Страница 55: ...Memo DV8650M_DC68 03170X 05_EN indd 55 2019 06 03 5 08 20 ...
Страница 57: ...Sèche linge Manuel d utilisation DVE G 52M8650 DV8650M_DC68 03170X 05_CFR indd 1 2019 06 03 5 07 07 ...
Страница 111: ...Mémo DV8650M_DC68 03170X 05_CFR indd 55 2019 06 03 5 07 20 ...
Страница 113: ...Secadora Manual del usuario DVE G 52M8650 DV8650M_DC68 03170X 05_MES indd 1 2019 06 03 5 07 39 ...
Страница 167: ...Notas DV8650M_DC68 03170X 05_MES indd 55 2019 06 03 5 07 52 ...