Ass’y Duct Heater (Electric)

 

Ass’y Duct (Gas)

 

Ass’y Fan

 

F0005 = DC47-00017A 

A0369 = DC47-00015A 

       F0005 = DC47-00018A 

Thermistor W0035 = DC32-00007A 

F0005 = DC47-00016A 

 CN1

 

1. AC Power Port 
2. AC Power off 
Detection Sensor 
3. Door Detection 
Sensor
(LOCK,UNLOCK) 

Relay 1                          
1 Motor Belt Sw (Brn)

  

2 120vac L1 (Blk)

 

Relay 6                                    
1 Heater Cut Off T-Stat (Blu)
2 120vac L1 (Blk)

 

 CN6

 

1. SET GND 

New Version of 
Blower Housing, it 
may be necessary to 
separate the harness 
wrap on replacement 
housing. Please 
maintain shielding 
on the low voltage 
wires.

 

 CN3

 

1. 5V 
2. SO 
3. SI 
4. RESET  
5. CLOCK 
6. FLMDO  
7. DGND 
8. Empty 
Pin 

 CN4

 

1. DGND 
2. 5V 
3. TEMP Sensor1 
4. Fabric Detection 
Sensor 
5. Fabric Detection 
Sensor 

 

6. 5V  
7. TEMP Sensor2 

         

 CN2

 

1. Communications Port(Rx) 
2. Communications Port(Tx) 
3. SUB RESET 
4. 5V 
5. DGND 
6. 12V 

             

 CN5

 

1. STEAM VALVE1 
2. Empty Pin 
3. LAMP 
4. Empty Pin 
5. STEAM VALVE2 
6. Empty Pin 

Содержание DV50FA9

Страница 1: ...r assume any liability for injury or damage of any kind arising from the use of this data sheet Models DV50FA9 Location consideration In the USA All Dryers Must be vented to the outside Only rigid or flexible metal duct should be used for venting Electrical Dryers 240 VAC 60 Hz 30 Amps 3 wire or 4 wire installations Gas Dryers 120 VAC 60 Hz 15 Amps 3 wire installations SUPPORT INFORMATION Training...

Страница 2: ......

Страница 3: ......

Страница 4: ...at Blu 2 120vac L1 Blk CN6 1 SET GND New Version of Blower Housing it may be necessary to separate the harness wrap on replacement housing Please maintain shielding on the low voltage wires CN3 1 5V 2 SO 3 SI 4 RESET 5 CLOCK 6 FLMDO 7 DGND 8 Empty Pin CN4 1 DGND 2 5V 3 TEMP Sensor1 4 Fabric Detection Sensor 5 Fabric Detection Sensor 6 5V 7 TEMP Sensor2 CN2 1 Communications Port Rx 2 Communications...

Страница 5: ...n to activate or deac tivate this feature The indicator light above the pad will illuminate when Wrinkle Prevent is selected Chasing lights appear in the display when the Wrinkle Prevent option is selected The load is dry and can be removed at any time during the Wrinkle Prevent cycle SUBJECT Dryer belt slides off the pulley when manually rotated counter clockwise ccw SYMPTOM The dryer drum will n...

Страница 6: ...r on start dryer read voltage between RY6 Blue wire and CN6 Green wire Reading of 120VAC means a proper operating heater circuit 0VAC means open in circuit To test thermostats use ohm meter on lowest scale any resistance replace component See page 4 for Main PCB layout for testing ...

Страница 7: ...age reading means Main PCB is defective See page 4 for Main PCB layout for testing Testing Motor circuit With power off read resistance between RY5 Brown and CN7 Blue Resistance reading of good motor circuit is about 1 9Ω To test thermostat and switch use ohm meter on lowest scale any resistance replace component See page 4 for Main PCB layout for testing ...

Отзывы: