Troubleshooting _ 35
4-5. COMPONENT TESTING PROCEDuRES
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing
requires power.
■
Component electrical testing (with ohmmeter)
• Thermistor resistance 10K Ω at 25°C 77°F (2P-Blue & Red wire)
• Thermostat 1 resistance < 1Ω (White & Yellow wire)
Thermostat 1
Thermistor
85 °C, 25A thermal cut-off
• Thermostat 3 resistance < 1Ω (Red & Black wire)
- If resistance is infinity, replace thermostat 3.
• Thermostat 2 resistance < 1Ω (Blue & Black wire)
- If resistance is infinity, replace thermostat 2.
• [DUAL] Heater resistance 13 Ω (PIN 2-3) Heater resistance 34 Ω (PIN 1-2)
- If resistance is infinity, replace Heater.
• [SINGLE] Heater resistance 10 Ω (PIN 1-3)
- If resistance is infinity, replace Heater.
• Measure resistance of the following terminal
1. Door switch knob: open
Terminal : “COM” - “NC” (1-3) < 1Ω
Terminal : “COM” - “NO” (1-2) : ∞ Ω
2. Door switch push: On
Terminal : “COM” - “NC” (1-3) : ∞ Ω
Terminal : “COM” - “NO” (1-2) < 1Ω
Door S/W
125V/10A
• Belt Cut-off S/W
- Lever open: Resistance value < 1Ω
- Lever push: Resistance value ∞ Ω
Belt cut-off S/W
125V, 15A
• Lamp resistance : ∞ Ω, (-) : BLU, (+) : WHT
DC3V, 45mA, 700Lux
Lamp
• Motor (Electronic & GAS)
Contacts ( : Contact closed)
Function
1M
2M
3M
5M
6M
Start
Run