Press the ‘Heavy’ + ‘Delicate’ + ‘Power’ buttons at the same time for two seconds to enter Service Inspection Mode.
•
All LEDs are displayed for the first two seconds and then Software-Ver. will be indicated.
•
You can change the mode by pressing the Normal button again. If press the Normal button in this mode, the mode
will be changed to next mode.
•
If you want to activate a mode while operating the dishwasher, the door must be closed.
•
If ‘LE’ , ‘OE’, ‘tE’ error occur, enter Service Inspection Mode after resolving it.
Service Inspection Mode is described in the following table.
SVC inspection Mode-
DMT800 series
Mode
Display
Related
Parts
Symptoms
Note
No.1
Ft
•
Drain
pump
•
Inlet
Valve
•
Flow
Meter
•
Water
Level Sen-
sor
•
Turbidity
Door open warn-
ing
Water supply
Error
Low level water
Error
Turbidity Error
If Door is open, Door open warning (dE) will blink.
If low level sensor is not detected, Drain is executed. Water supply will be
executed when low level sensor is detected.
If water is not fully supplied (sensing on flow-meter), the Water Supply Error
(4E) will blink.
When high level sensor is not detected after water supply was done, Low-
level water error (9E) will blink.
When Turbidity problem is occurred after water supply was done, Turbidity
Error (AE) will blink.
If all functions in this mode are completed, ‘Ft’ and ‘3.6~3.9’ will blink.
No.2
Lc
•
Circulation
Motor
A nozzle does not
inject water.
If Low Level sensor is detected before Circulation Motor is operating, ‘LL’
and ‘Lc’
will blink.
When water is filled enough, Circulation Motor -2(190W) will be operated.
No.3
Ld
•
Circulation
Motor
A nozzle does not
inject water.
If Low Level sensor is detected before Circulation Motor is operating, ‘LL’
and ‘Ld’
will blink.
When water is filled enough, Circulation Motor- 1(150W) will be operated.
No.4
Hd
•
Circulation
Mo-
tor
•
Heater
•
T
hermistor
•
Dis
penser
Heater Error
If Low Level sensor is detected before Circulation Motor is operating, ‘LL’
and ‘Hd’
will blink.
When water is filled enough, Circulation Motor 1(150W) and Heater will be
operated.
‘Temperature[
Ԩ
]’ and ‘Hd’ will blink.
When the temperature meet 60
Ԩ
or above, the heater is turned off.
If Heater or Thermistor have problems, the Heater Error (HE) will blink.
Dispenser will operate during 130 seconds only one time.
No.5
SH
•
Half Load
Motor
Half load func-
tion Error
If Low Level sensor is detected before Circulation Motor is operating, ‘LL’
and ‘SH’
will blink.
When water is filled enough, Half Load Motor will be operated, and then
Half load function will be operated.
No.6
SP
•
Half Load
Motor
Storm wash func-
tion Error
If Low Level sensor is detected before Circulation Motor is operating, ‘LL’
and ‘SP’
will blink.
When water is filled enough, Half Load Motor will be operated, and then
Storm wash function will be operated.
No.7
dF
•
Dry Fan
Mtr
•
Dispens
The Dry Fan mo-
tor does not work.
Operate the Dry Fan Motor and check whether Rinse aid is filled or not.
If there is not rinse aid in Dispenser, Rinse Refill lamp is ON.
No.8
L
•
Inlet
valve
•
Overflow
Sensor
Over level wa-
ter Error
Water is supplied until Over-level water error (oE) is blinked.
If Over-level water error (oE) occurs, overflow sensor is OK.