Code 

sym-

bol

 

Meaning

 

Occurring condition

 

Expected condition

 

 

Temp sen-
sor

 

Error

 

When 0.2V or below, or 4.5V or above is main-
tained for over 3 seconds

 

Thermistor terminal is not connected

 

Possible defect : Thermistor , Main 
PBA

 

HE

 

Heater  
Error

 

When the temperature change is 4

Ԩ

 or less 

within the first 10 minutes after the heating 
starts

 

Heater terminal is not connected

 

Possible defect :  Main Wire-Harness, 
Heater, Main PBA

 

1E

 

High temp 

Heating 

error. 

 

When the temp of the Thermistor is 80

Ԩ

 or 

above for more than 3 seconds during opera-
tion.

 

Water  temp is 80

Ԩ

 or above

 

Possible defect :  Thermistor , Main 

PBA

 

9E

 

Low-level 

water   

error 

 

1.When high level sensor is not detected after 

water supply was done, drain & refill the 
water. After then, if high level sensor is not 
detected again, this error is occurred.

 

2.When low level sensor is detected over 5 sec-

onds during wash operation, this error is 
occurred.

 

Water Level Sensor terminal is not 
connected

 

Possible defect :  Assy case sensor, 
Water Level Sensor , Main PBA

 

PE

 

Half load 

function 

error  

 

When micro s/w is not detected for over 30 sec-
onds after the Distributor motor starts

 

Distributor motor defect

 

Micro SW terminal is not connected

 

Main PBA defect

 

4E

 

Water 

supply 

error 

 

 

 

1. When the pulse of 100 or less is detected 

even 73 seconds after the water supply

 

2. When flow meter pulse is 5 or less for 13 sec-

onds after the water supply starts

 

3. When the water supply is not finished until 6 

minutes after the water supply starts

 

Alien particles within water supply 

valve

 

Water supply valve terminal not con-

nected

 

Possible defect :  Main PBA, Water 

supply valve , Flow Meter

 

3E

 

High temp 

Water 

supply 

error

 

When 80

Ԩ

 or above is detected during water 

supply

 

Water supply temperature is 80

Ԩ

 or 

above

 

Possible defect :  Thermistor,  Main 

PBA

 

5E

 

Drain   

error 

 

When OFF status of Low Level S/W is not de-
tected within 3 minutes during the drain. 

 

Alien particles are clogging in drain 

hose

 

Drain pump terminal is not connected

 

Possible defect : Drain pump, Water 

Level Sensor , Main PBA

 

oE

 

Over-level 

water  er-

ror

 

When overflow detection AD data is 3.5V or be-

low for 3 seconds

 

(When leakage sensor detects 3.5V or below for 

1 seconds during water supply)

 

Alien particles within water supply 

valve

 

Case Sensor part breakdown

 

Possible defect : Flow Meter, Main 

PBA, Water supply valve

 

LE

 

Leakage

 

 

When leakage sensor detects 3.5V or below for 
1 seconds

 

Possible defect : Each hose connec-

tion ,  Sump and Tub assembly, Drain 

Pump assembly , Main PBA

 

bE

 

Button 

error 

 

When the button is pressed continuously for 
over 10 seconds

 

Possible defect : Sub PBA in

 

control  

panel, Main PBA

 

dE

 

Door open 

warning

 

When door is open in washing period.

 

 

Door is not close properly in test 
mode only.

 

Possible defect : Door lock switch, 
Main PBA

 

Error Codes - 

DMT800 series

 

5

Содержание DMT800RHB/XAA

Страница 1: ...ine bleach will work on the stains much better than an Enzyme based detergent Cycle Pre wash 1 Pre wash 2 Main wash Rinse 1 Rinse 2 Rinse 3 Last Rinse Sanitize Dry min Water gal ℓ Time min Normal Flex 120 138 F 49 59 C Flex x 136 F 58 C 162 F 72 C 30 3 6 6 7 13 6 25 2 110 132 Heavy 140 F 60 C 158 F 70 C 162 F 72 C 40 8 1 30 6 152 Deli cate x 122 F 50 C x 140 F 60 C 30 4 7 17 7 107 Pot Pans 131 F 5...

Страница 2: ...2 ...

Страница 3: ... CN101 3 Disp Wax Mtr Wht Yel 120vac 3 CN101 3 Half Load Vio Yel 120vac 5 CN101 3 Fan Mtr S Blu Yel 120vac 7 CN101 3 Wash Mtr Blu Yel 120vac 9 CN101 3 Wash Mtr Wht Yel 120vac CN202 1 CN101 3 Valve Brn Yel 120vac 5 CN101 3 Pump Org Yel 120vac CN102 1 6 S Blu S Blu 5vdc 2 6 S Blu S Blu 12vdc CN501 3 1 5vdc T202 CN101 3 Heater Red Yel 120vac T201 L1 Blk 120vac Assy Case Vent Assy Dry Duct Assy Duct C...

Страница 4: ...ng latch 3 If the customer uses tablets or some self contained type of soap tab make sure it is fully seated and the door does not sandwich it shut 4 Make sure that in the rack nearest to the dispenser door when the door is shut is not obstructing the opening of the dispenser with some protruding utensil Testing The Detergent Door and Dispenser 1 Disconnect wires from disp close detergent door 2 C...

Страница 5: ...fter the water supply 2 When flow meter pulse is 5 or less for 13 sec onds after the water supply starts 3 When the water supply is not finished until 6 minutes after the water supply starts Alien particles within water supply valve Water supply valve terminal not con nected Possible defect Main PBA Water supply valve Flow Meter 3E High temp Water supply error When 80Ԩ or above is detected during ...

Страница 6: ...c will blink When water is filled enough Circulation Motor 2 190W will be operated No 3 Ld Circulation Motor A nozzle does not inject water If Low Level sensor is detected before Circulation Motor is operating LL and Ld will blink When water is filled enough Circulation Motor 1 150W will be operated No 4 Hd Circulation Mo tor Heater T hermistor Dis penser Heater Error If Low Level sensor is detect...

Страница 7: ...oad Key is pressed Half Load Motor is On Half Load LED On and pressed again it is Off Half Load LED Off When a different key is pressed during individual operation of the oper ating part present operating part is stopped and the applicable operation for the pressed key will start Press the Heavy Delicate Power buttons at the same time for two seconds to enter Service Inspection Mode All LEDs are d...

Отзывы: