Error Type
Error Mode
Checking Method
Corrective actions
Heater Error
„Heavy‟ +
„Delicate‟ LED
1. Check the connections of the Heater connectors.
- Reconnect the Heater connectors.
2. Check the resistance between both ends of the Heater.
: Check the resistance between both ends of the Heater
directly, or check
the resistance between the red wire of the Heater Relay
and the amber
and yellow wires of the Power Relay, respectively.
➢
Normal: Approx. 13Ω
Check after disconnect circuit breaker or power cable.
- Faulty: Replace the Heater.
3. Check the connections of the Heater Relay.
: Check the voltage between the red wire of the Heater
Relay on the base and the yellow and amber wires of the
Power Relay.
➢
Normal: 120V (while operating)
- Reconnect the Heater Relay connectors.
4-1.Check the driving signals for the Heater Relay.
- Measure the voltage between pin 6 (amber) of the Main
PBA CN302 connector and pin 2 (red) of the CN302
connector.
➢
When the Heater is off: 9.5 to 12.5V
➢
When the Heater is operating: < 0.5V
- Faulty: Replace the Main PBA assy.
- Normal: Replace the Heater Relay.
- Remove Retainer.
- Check voltage
Trouble Shooting
Содержание DMT300 Series
Страница 1: ...Dishwasher DMT300 series training Jan 2010 Kitchen Solution Business Team...
Страница 4: ...Features Dishwasher Features...
Страница 5: ...Functions Control Panel...
Страница 8: ...Wiring Diagram...
Страница 9: ...Schematic diagram...
Страница 10: ...Schematic...
Страница 11: ...Schematic...
Страница 12: ...Schematic Sub PCB...
Страница 36: ...Trouble Shooting Program chart...
Страница 51: ...Model Number Naming Rules...
Страница 52: ...Thanks SAMSUNG...